RS PRO RSDS 1052 DL+

RS PRO RSDS 1052 DL+ санариптик сактагыч осциллографынын колдонуучу колдонмосу

Model: RSDS 1052 DL+

1. Киришүү

This manual provides comprehensive instructions for the safe and effective operation, maintenance, and troubleshooting of the RS PRO RSDS 1052 DL+ Digital Storage Oscilloscope. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage or injury.

The RS PRO RSDS 1052 DL+ is a versatile 2-channel digital storage oscilloscope with a 50 MHz bandwidth, designed for precise signal analysis. It features a 7-inch TFT LCD display for clear waveform visualization and supports various measurement parameters and mathematical operations.

2. Коопсуздук маалыматы

Always adhere to the following safety precautions to prevent electric shock, fire, or damage to the instrument.

3. Продукт бүтүп калдыview жана компоненттер

Бул бөлүм ашыкча камсыз кылатview of the RS PRO RSDS 1052 DL+ oscilloscope and its main components.

Фронт view of the RS PRO RSDS 1052 DL+ Digital Storage Oscilloscope

Сүрөт 3.1: Алдыңкы View of the Oscilloscope. This image shows the front panel of the RS PRO RSDS 1052 DL+ oscilloscope, highlighting the 7-inch TFT LCD display, control knobs, function buttons, and input connectors for channels 1 and 2. The screen displays a typical waveform and FFT analysis.

Бурчтуу view of the RS PRO RSDS 1052 DL+ Digital Storage Oscilloscope

3.2-сүрөт: Бурчтуу View of the Oscilloscope. This image provides an angled perspective of the RS PRO RSDS 1052 DL+ oscilloscope, showcasing its compact design and integrated handle for portability. The side ventilation grilles are also visible.

Арткы view of the RS PRO RSDS 1052 DL+ Digital Storage Oscilloscope showing connectivity ports

3.3-сүрөт: Арткы View of the Oscilloscope. This image displays the rear panel of the RS PRO RSDS 1052 DL+ oscilloscope, featuring the power input, USB device port, USB host port, LAN port, and Pass/Fail output. Safety warnings and product labels are also visible.

Oscilloscope probe and accessories

Figure 3.4: Oscilloscope Probe and Accessories. This image shows a passive oscilloscope probe (1:1/10:1) along with various accessories, including colored rings for channel identification and probe tip covers. These are essential for connecting signals to the oscilloscope.

Assortment of power plugs and a probe tip

Figure 3.5: Power Plugs and Probe Tip. This image displays an assortment of power plugs (EU, UK, US types) that may be included with the oscilloscope, along with a specialized probe tip. These ensure compatibility with various power outlets and provide versatility for measurements.

3.1 Кошумча жабдуулар

The RS PRO RSDS 1052 DL+ typically includes the following accessories:

4. Орнотуу

4.1 Таңгактан чыгаруу жана текшерүү

  1. Carefully remove the oscilloscope and all accessories from the packaging.
  2. Inspect the instrument for any signs of physical damage during transit. If damage is found, contact your supplier immediately.
  3. Verify that all included accessories listed in Section 3.1 are present.

4.2 Кубат туташтыруу

  1. Арткы панелдеги кубат которгучу ӨЧҮРҮҮ абалында экенин текшериңиз.
  2. Connect the provided power cord to the AC input on the rear panel of the oscilloscope.
  3. Plug the other end of the power cord into a grounded AC power outlet. The oscilloscope supports 100-240V AC, 50/60Hz.

4.3 Зондду туташтыруу жана компенсациялоо

  1. Connect the BNC connector of the passive probe to one of the input channels (CH1 or CH2) on the front panel.
  2. Attach the probe tip to the probe compensation output (usually a square wave test signal) on the front panel.
  3. Adjust the compensation trimmer on the probe until the displayed square wave is flat-topped, without overshoot or undershoot. This ensures accurate measurements.

5. Иштөө нускамалары

5.1 Негизги операция

5.2 Өркүндөтүлгөн функциялар

6. Техникалык тейлөө

6.1 Тазалоо

6.2 Калибрлөө

The oscilloscope is factory calibrated. For optimal performance, periodic calibration by qualified personnel is recommended, typically every 12-24 months, depending on usage and environmental conditions.

6.3 Сактоо

When not in use for extended periods, store the oscilloscope in a dry, dust-free environment, away from extreme temperatures and humidity.

7. Кыйынчылыктарды

Бул бөлүмдө сиз кабылышы мүмкүн болгон жалпы маселелерди чечүү жолдору каралган.

КөйгөйМүмкүн себепЧечим
Күч жокPower cord disconnected; Power switch off; Blown fuseCheck power cord connection; Turn power switch on; Contact service for fuse replacement.
Толкун формасы көрсөтүлгөн жокInput signal too small/large; Incorrect vertical/horizontal settings; Trigger not set correctly; Probe not connectedAdjust VOLTS/DIV and SEC/DIV; Use Auto Setup; Adjust trigger level; Ensure probe is connected and compensated.
Туруксуз толкун формасыIncorrect trigger settings; No trigger source selectedAdjust trigger level and mode; Select appropriate trigger source (e.g., CH1, CH2, Ext).
Бурмаланган толкун формасыProbe compensation incorrect; Probe damaged; Input overloadedPerform probe compensation; Try a different probe; Check input signal ampжарыктык.

If the problem persists after attempting these solutions, please contact RS PRO customer support.

8. Техникалык шарттар

Key technical specifications for the RS PRO RSDS 1052 DL+ Digital Storage Oscilloscope:

9. Кепилдик жана колдоо

RS PRO products are manufactured to high standards and are typically covered by a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official RS PRO webдеталдуу кепилдик шарттары жана шарттары үчүн сайт.

For technical support, service, or inquiries regarding your RS PRO RSDS 1052 DL+ oscilloscope, please contact RS PRO customer service through their official channels. Contact information can usually be found on the RS PRO website or in the documentation provided with the product.

RS PRO Official Webсайт: https://uk.rs-online.com/web/

Тектеш документтер - RSDS 1052 DL+

Preview RS PRO 9-Way D-Sub Male Panel Mount Connector | RS 473-880
High-performance RS PRO 9-way male D-Sub connector (RS 473-880) for panel mounting. Features RS232 interface, solder termination, gold-plated copper alloy contacts, and robust steel housing. Ideal for industrial and commercial I/O applications.
Preview RS PRO Connettore Maschio D-Sub 9 Vie 473-880 - Specifiche Tecniche
Scheda tecnica dettagliata per il connettore maschio D-Sub RS PRO 473-880. Caratteristiche, specifiche elettriche, meccaniche e ambientali per applicazioni industriali.
Preview Ringbrothers 1051-1052 Billet Hood Hinge Kit Installation Instructions
Comprehensive installation guide for the Ringbrothers 1051-1052 Billet Hood Hinge Kit, featuring step-by-step instructions, packing list, required tools, and detailed parts identification for vehicle applications.
Preview FNIRSI-138 Pro Digital Oscilloscope Колдонуучунун колдонмосу
User manual for the FNIRSI-138 Pro Digital Oscilloscope, covering product introduction, panel and button functions, icon indications, parameter index, firmware upgrades, common problem analysis, and production information.
Preview FNIRSI-138 Pro Digital Oscilloscope Колдонуучунун колдонмосу
FNIRSI-138 Pro колдук санариптик осциллографы үчүн комплекстүү колдонуучу колдонмосу, анда продукттун киришүүсү, панелдин жана баскычтардын функциялары, сөлөкөттүн көрсөткүчтөрү, техникалык мүнөздөмөлөр, микропрограмманын жаңыртуулары жана көйгөйлөрдү чечүү боюнча жалпы кеңештер камтылган.
Preview FNIRSI-138 Pro Digital Oscilloscope User Manual - Model M469A
Comprehensive user manual for the FNIRSI-138 Pro digital oscilloscope (Model M469A). Covers specifications, panel layout, button operations, icon meanings, troubleshooting, firmware updates, and maintenance. Features 200kHz bandwidth, 2.5 MS/s sampling rate, and a 2.4-inch LCD.