1. Продукт бүтүп калдыview
The Elitech Inframate C Infrared R-744 Refrigerant Leak Detector is engineered for precise and reliable detection of carbon dioxide (CO2) leaks in various applications. Utilizing an advanced infrared sensor, it offers high sensitivity and rapid response, making it an essential tool for professionals.
Негизги өзгөчөлүктөр төмөнкүлөрдү камтыйт:
- Advanced Infrared Sensor: Provides stable and accurate detection with a low possibility of contamination and strong anti-interference ability. The sensor boasts an impressive life of 40,000 hours.
- Higher Sensitivity: Adaptive sensitivity allows detection of leaks as small as 6g/year.
- Large TFT LCD Display: Clearly shows leakage levels using colorful bars, enhancing user experience and intuitive result presentation.
- Колдонууга оңой: Equipped with a flexible stainless steel probing rod to reach difficult areas.
- Коопсуз жана ишенимдүү: Features rechargeable and replaceable batteries for environmental friendliness and convenience.

Figure 1: Elitech Inframate C Infrared R-744 Refrigerant Leak Detector
2. Пакеттин мазмуну
Пакетти ачкандан кийин, төмөнкү нерселердин бардыгы камтылганын текшериңиз:
- 1 x Leak Detector
- 1 x User Manual
- 1 x USB кабели
- 1 х адаптер
- 1 x Packet of Filters (5 filters)
- 1 x UV Light
- 1 x Extension Pole

Figure 2: All items included in the Elitech Inframate C package
3. Орнотуу жана иштетүү
3.1 Компонентти идентификациялоо

Figure 3: Labeled components of the Elitech Inframate C, including flexible probe, UV LED, filter components, 3.5mm headphone jack, USB port (Type-C), display screen, buttons, and buzzer.
3.2 Powering On and Warm-up
To power on the detector, press the КҮЙГҮЗҮҮ/ӨЧҮРҮҮ button. The device will enter a warm-up phase, which takes approximately 30 seconds. During this time, the display will show a warming-up message. Once warmed up, it will enter the infrared detection interface with a continuous beeping sound on standby.
3.3 Сезгичтикти жөндөө
The SENS button allows you to adjust the detection sensitivity. You can cycle through High (H), Medium (M), and Low (L) levels as needed. The default sensitivity level is Medium (M).
3.4 Leak Detection and Automatic Reset
The Elitech Inframate C features an automatic reset function. This function resets the leaking level every 3 seconds, which is crucial for helping users pinpoint the exact leaking source by allowing the device to re-calibrate to the ambient air and then react to the leak as you move the probe.
3.5 Recording Peak Levels
басыңыз ПИК button to record the current peak level of refrigerant concentration detected. Pressing it again will clear the recorded peak value.
3.6 Үнсүз кылуу функциясы
To mute the continuous beeping sound during standby or operation, press the БАСУУ баскычы.
3.7 Өчүрүү
Детекторду өчүрүү үчүн басып, кармап туруңуз КҮЙГҮЗҮҮ/ӨЧҮРҮҮ баскычын 2 секунда басыңыз.
3.8 Иштөөнү көрсөтүү
Video 1: A comprehensive demonstration of the Elitech Inframate C's features, including power-on, warm-up, sensitivity adjustment, automatic reset for leak detection, peak recording, and power-off procedures.
4. Маанилүү ойлор
To ensure accurate readings and prolong the life of your detector, please observe the following:
- Контаминанттардан алыс болуңуз: Leaking areas are often covered with substances like compressor oil or dirt. It is crucial to prevent the sensor tip from coming into contact with these contaminants, as they can affect detection accuracy and sensor longevity.
- Кургак кармоо: Keep the sensor tip away from any moisture or other solvents to avoid false alarms and potential damage to the sensor.
- Wear Face Mask: When using the highest sensitivity setting, it is recommended to wear a face mask to avoid faulty alarms caused by exhaled breath.
5. Техникалык шарттар
| Спецификация | Нарк |
|---|---|
| Бренд | Элитех |
| Модел | Inframate-C-US |
| Power Source | Батарея менен иштейт (2 литий-иондук батарейкалар камтылган) |
| Түс | CO2 Detect |
| Продукциянын өлчөмдөрү | 1.4"D x 2.8"W x 7.9"H |
| Элемент Салмагы | 16 Ounces (approx. 1 pound) |
| Ойготкуч | Audible, Visual |
| Иштөө нымдуулугу | Максималдуу 90% RH (конденсацияланбайт) |
| Жогорку температура рейтинги | 52 градус |
| Сенсор түрү | Инфракызыл |
| Сезимталдуулук | 6g/year (0.21oz/yr) |
| Заряддоо Voltage/Current | DC 5V, 1A |
| Заряддоо убактысы | Болжол менен 4 саат |
| Иштөө убактысы | 11 саат |
| Иштөө температурасы диапазону | -10°C ~ 52°C |

Figure 4: Detailed specifications of the Elitech Inframate C Leak Detector.
6. Техникалык тейлөө
Proper maintenance ensures the longevity and accuracy of your Elitech Inframate C Leak Detector:
- Сенсорго кам көрүү: The infrared sensor is a critical component. Avoid exposing the sensor tip to compressor oil, dirt, moisture, or other solvents, as these can contaminate or damage it, leading to inaccurate readings or malfunction.
- Тазалоо: Regularly wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the probe and sensor tip are clean before and after each use.
- Фильтрди алмаштыруу: The device comes with a packet of filters. Replace filters periodically or if you notice a decrease in performance or increased false alarms, especially when operating in dusty environments.
- Батарея башкаруу: Use only the specified rechargeable batteries. Ensure they are properly charged before use and replaced when their performance degrades.
- Сактагыч: Store the detector in its protective case in a cool, dry place away from direct sunlight, extreme temperatures, and corrosive substances.
7. Кыйынчылыктарды
Бул жерде кээ бир жалпы маселелер жана алардын мүмкүн болуучу чечимдери:
7.1 Device Beeps Continuously Upon Power On
Маселе: The device starts beeping immediately when turned on.
Чечим: This is normal behavior. The device beeps upon powering on. The alarm sound becomes more urgent when a leak is detected.
7.2 Leaks Cannot Be Detected
Маселе: The detector fails to identify leaks.
Чечимдер:
- The product automatically calibrates. After moving away from a suspected leak point, approach it multiple times to confirm if a leak is present.
- Check if the sensor is damaged.
- Verify if the air pump has lost suction capability.
- Inspect for any blockages in the internal pipeline.
7.3 Product Alarms in Non-Leaking Environment
Маселе: The detector triggers an alarm even when no leak is present.
Чечимдер:
- Deformation of the optical chamber can affect detection data; this is a normal occurrence.
- A loose critical optical filter might be the cause. Contact support for repair assistance if this is suspected.
- Check for routers or other electronic devices nearby that might be causing electromagnetic interference.
8. Кепилдик жана колдоо
Elitech provides comprehensive customer support for the Inframate C Infrared R-744 Refrigerant Leak Detector.
- Техникалык колдоо: Enjoy 24/7 US Technician Support via Email and Phone for any operational or technical queries.
- Кепилдик маалыматы: Please refer to the warranty card included in your product package for detailed terms and conditions regarding your device's warranty.
For further assistance, please visit the official Elitech webсайтка же түздөн-түз кардарларды тейлөөгө кайрылыңыз.