1507

Fluke 1507 Digital Megohmmeter Insulation Resistance Tester User Manual

Модель: 1507

1. Киришүү

The Fluke 1507 Digital Megohmmeter Insulation Resistance Tester is a robust and reliable instrument designed for comprehensive insulation testing in industrial and electrical environments. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your Fluke 1507 tester.

Key features include multiple insulation test voltages, automatic calculation of Polarization Index (PI) and Dielectric Absorption Ratio (DAR), a Compare (Pass/Fail) function for repetitive testing, and live circuit detection for enhanced safety.

2. Коопсуздук маалыматы

WARNING: Always read and understand all safety information before operating the Fluke 1507 tester. Failure to do so may result in serious injury or death.

3. Components and Included Accessories

The Fluke 1507 Insulation Resistance Tester package typically includes the following items:

Fluke 1507 Insulation Tester with included accessories
Figure 3.1: The Fluke 1507 Insulation Tester shown with its standard included accessories, including test leads, probes, alligator clips, and the remote probe.

4. Орнотуу

4.1. Батареяны орнотуу

The Fluke 1507 requires four AA alkaline batteries for operation. These are typically included with the unit. To install or replace batteries:

  1. Сыноочу өчүк экенин текшериңиз.
  2. Бирдиктин артындагы батарея отсегин табыңыз.
  3. Батарея бөлүкчөсүнүн капкагын ачуу үчүн бурагычты колдонуңуз.
  4. Insert the four AA batteries, observing the correct polarity as indicated inside the compartment.
  5. Батарея уясынын капкагын ордуна коюңуз жана аны бурама менен бекитиңиз.

4.2. Сыноо линияларын туташтыруу

Connect the test leads to the appropriate input jacks on the tester. For insulation resistance measurements, use the 'V Ω' and 'COM' jacks. Ensure connections are secure before proceeding with any tests.

5. Иштөө нускамалары

5.1. Күйгүзүү / Өчүрүү

To power on the Fluke 1507, rotate the rotary switch from the 'OFF' position to any desired measurement function. The large, backlit display will illuminate. To power off, rotate the switch back to 'OFF'. The unit also features an auto-power off function to conserve battery life.

Фронт view of the Fluke 1507 Insulation Tester display and controls
Figure 5.1: The front panel of the Fluke 1507, showing the display, rotary switch, and function buttons.

5.2. Тесттин томун тандооtages

The Fluke 1507 offers multiple insulation test voltages. Rotate the main rotary switch to the 'INSULATION' section. Then, use the dedicated voltage selection buttons (50 V, 100 V, 250 V, 500 V, 1000 V) to choose the appropriate test voltagСиздин арызыңыз үчүн.

5.3. Performing Insulation Tests

Once the desired test voltage is selected and test leads are connected to the circuit under test:

  1. басып, кармап туруңуз СЫНОО button to initiate the insulation test. The display will show the measured insulation resistance.
  2. For hands-free operation during repetitive tests, utilize the remote test probe.
  3. The live circuit detection feature will prevent a test if voltage exceeds 30V, indicated by a warning on the display.
Fluke 1507 Insulation Tester held in a gloved hand during operation
Figure 5.2: The Fluke 1507 being held by a technician, demonstrating its compact and ergonomic design for field use.
Technician using Fluke 1507 to test an industrial motor
Figure 5.3: A technician performing an insulation test on an industrial motor using the Fluke 1507, highlighting its application in preventative maintenance.

5.4. Compare (Pass/Fail) Function

The Compare (Pass/Fail) function simplifies repetitive testing by allowing you to set a pass/fail threshold. Refer to the on-screen prompts and the user interface for setting this function. The tester will then indicate whether the measured resistance meets the predefined criteria.

5.5. Поляризация индекси (PI) жана диэлектриктердин абсорбция катышы (DAR)

The Fluke 1507 automatically calculates Polarization Index (PI) and Dielectric Absorption Ratio (DAR), saving time and ensuring accurate assessment of insulation condition. These functions are typically accessed via dedicated buttons on the front panel.

Technician using Fluke 1507 with magnetic hanging system for overhead work
Figure 5.4: A technician utilizing the optional magnetic hanging system with the Fluke 1507, allowing for hands-free operation during overhead electrical work.

6. Техникалык тейлөө

6.1. Тазалоо

To clean the exterior of the tester, use a damp cloth and a mild detergent. Do not use abrasive cleaners or solvents. Ensure the unit is completely dry before storage or next use.

6.2. Батареяны алмаштыруу

Replace batteries when the low battery indicator appears on the display. Refer to Section 4.1 for detailed battery installation instructions. Always use fresh alkaline batteries.

6.3. Калибрлөө

For optimal performance and accuracy, periodic calibration by an authorized service center is recommended. Refer to your warranty information or contact Fluke support for calibration schedules and services.

7. Кыйынчылыктарды

This section provides solutions to common issues you might encounter with your Fluke 1507 tester.

КөйгөйМүмкүн себепЧечим
Сыноочу күйгүзүлбөйт.Өлүк же туура эмес орнотулган батарейкалар.Батареянын полярдуулугун текшерип, жаңы AA батарейкалары менен алмаштырыңыз.
Insulation test does not start.Live тtage detected on the circuit.Ensure the circuit is de-energized or voltage is below 30V. The tester will not perform an insulation test if live voltage is present for safety.
Туура эмес окуулар.Damaged test leads or improper connection.Inspect test leads for damage. Ensure leads are securely connected to the tester and the circuit.
Дисплей күңүрт же бүлбүлдөп турат.Батарея аз.Батареяларды алмаштырыңыз.

8. Техникалык шарттар

СпецификацияНарк
БрендFluke
Модель номери1507
Power SourceБатарея менен иштейт (4 AA батарейка)
Insulation Test Voltages50 В, 100 В, 250 В, 500 В, 1000 В
Мин. Operating Voltage50 вольт (ток)
Тtage Рейтинг600 вольт
Өлчөө тактыгы+/-0.5%
Элемент Салмагы2.2 фунт (1 килограмм)
Продукциянын өлчөмдөрү (L x W x Y)11.77 x 15.2 x 3.07 дюйм
МатериалПластик
ТүсСары
ШайкештикEN 61010-1, CAT IV 600 V
Камтылган компоненттерRemote probe, test leads, test probes, alligator clips

9. Кепилдик жана колдоо

9.1. Кепилдик маалыматы

The Fluke 1507 Digital Megohmmeter Insulation Resistance Tester comes with a 1-Year warranty. Please retain your proof of purchase for warranty claims. The warranty covers defects in materials and workmanship under normal use.

9.2. Кардарларды колдоо кызматы

For technical assistance, service, or to inquire about calibration services, please visit the official Fluke website or contact their customer support. You can also refer to the comprehensive User Manual (PDF) available online for more detailed information:

Тектеш документтер - 1507

Preview Fluke 1535/1537/1537-II Insulation Tester User Manual
Comprehensive user manual for Fluke 1535, 1537, and 1537-II Insulation Testers, covering features, operation, testing procedures, maintenance, and specifications.
Preview Fluke 1550C/1555 Insulation Tester Users Manual
User manual for the Fluke 1550C and 1555 Insulation Testers, detailing features, operation, measurements, maintenance, and specifications.
Preview Fluke SMFT-1000: Voc and Operational Current Testing Guide for PV Systems
This application note from Fluke Corporation details how to perform Voc (Open Circuit Voltage) and Ioperational (Operational Current) tests on photovoltaic (PV) modules and strings using the Fluke SMFT-1000 tester, adhering to IEC 62446-1 standards. It provides step-by-step instructions and explains the interpretation of test results for ensuring PV system performance and identifying wiring faults.
Preview Fluke 1507/1503 изоляциялык сыноочуларынын колдонуучу колдонмосу
Fluke 1507 жана 1503 изоляциялык сыноочулары үчүн кеңири колдонуучу колдонмосу, анда иштөө, коопсуздук чаралары, өлчөө процедуралары, техникалык мүнөздөмөлөр жана тейлөө жөнүндө кеңири маалымат берилген.
Preview Fluke SMFT-1000 Multifunction PV Analyzer Quick Reference Guide
A quick reference guide for the Fluke SMFT-1000 Multifunction PV Analyzer, providing step-by-step instructions for essential solar photovoltaic system tests including loop resistance, polarity, Voc/Isc, insulation resistance, and I-V curve tracing.
Preview Fluke T5-1000 / PRV240 Proving Unit Kit: Technical Data and Ordering Information
Comprehensive technical data and ordering information for the Fluke T5-1000 Electrical Tester and PRV240 Proving Unit Kit, detailing product specifications, components, and Fluke Corporation contact details.