This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Goodman Mini-Split AC/Heating System E-Series. Please read this manual thoroughly before installation and use, and retain it for future reference. This system is designed to provide efficient heating and cooling for residential and light commercial applications.

Орнотуу жана орнотуу

The Goodman Mini-Split AC/Heating System E-Series includes an indoor wall-mounted air handler unit, an outdoor mini-split heat pump condenser, and a comprehensive installation kit. Professional installation is recommended for optimal performance and safety.

Компоненттер камтылган

Goodman Mini-Split AC/Heating System E-Series with all components

Figure 1: ашыкview of the Goodman Mini-Split AC/Heating System E-Series and its included components, showing the indoor unit, outdoor unit, remote control, and installation kit elements.

Орнотуу маселелери

Ensure the installation area for both indoor and outdoor units meets the required clearances for proper airflow and maintenance. The system operates on 208/230V, 1 Phase, 60Hz power. The 0.75-ton unit is designed to efficiently heat and cool areas up to 400 square feet.

ACiQ Mini Split Installation Kit components

2-сүрөт: Детальдуу view of the ACiQ Mini Split Installation Kit, including line sets, control wire, drain tube, wall mount bracket, and line cover guards.

Иштөө нускамалары

Your Goodman E-Series Mini-Split system offers various modes and features for optimal comfort and energy efficiency.

Негизги иштөө режимдери

Негизги өзгөчөлүктөр жана башкаруу элементтери

Goodman E-Series Mini-Split features list

Figure 3: Illustration of the key features of the Goodman E-Series Mini-Split system, including remote control, auto-restart, self-diagnosis, and various operational modes.

Техникалык тейлөө

Regular maintenance ensures the longevity and efficient operation of your mini-split system. Always disconnect power to the unit before performing any maintenance.

Фильтрди тазалоо

The system is equipped with a Catechin Air Quality Filter System and a Titanium Apatite Deodorising Filter. These filters should be cleaned regularly, typically every 2-4 weeks depending on usage and air quality. Refer to the specific instructions in your full product manual for filter removal and cleaning procedures. Generally, filters can be gently vacuumed or washed with lukewarm water and mild detergent, then air-dried completely before reinstallation.

Drain Pan Maintenance

The indoor unit features a removable dirt-water drain pan. Periodically inspect and clean the drain pan to prevent mold growth and blockages, which can lead to water leaks. Ensure the drain tube is clear and free of obstructions.

Бирдикти тазалоо

The indoor unit has a wipe-clean flat panel. Use a soft, damp cloth to clean the exterior surfaces. Do not use harsh chemicals or abrasive cleaners. For the outdoor unit, ensure the coils are free of debris and obstructions. The outdoor unit also features anti-corrosion treatment for enhanced durability.

Проблемаларды чечүү

Before contacting customer support, please refer to the following common issues and solutions. The self-diagnosis feature with a digital display can provide initial indications of problems.

КөйгөйМүмкүн себепЧечим
Түзмөк күйбөйтNo power, remote control batteries low, unit switch off.Check power supply, replace remote batteries, ensure indoor unit ON/OFF switch is engaged.
Жылытуу/муздатуу жетишсизDirty air filters, blocked outdoor unit, incorrect mode/temperature setting, refrigerant leak.Clean filters, clear obstructions from outdoor unit, verify settings, contact professional for refrigerant check.
Адаттан тышкаркы ызы -чууLoose parts, fan obstruction, refrigerant flow noise (normal).Inspect for loose parts or obstructions. If noise persists or is abnormal, contact service.
Ички блоктон суунун агып чыгышыClogged drain pan/tube, improper installation.Clean drain pan and tube. If issue persists, professional inspection is required.
Digital display shows error codeИчки системанын катасы.Note the error code and consult the full product manual or contact customer support for specific guidance.

For issues not listed or if troubleshooting steps do not resolve the problem, please contact a qualified HVAC technician or ACiQ customer support.

Техникалык шарттар

Detailed technical specifications for the Goodman Mini-Split AC/Heating System E-Series (0.75 Ton, 9000 BTU).

АтрибутНарк
Бренд атыACiQ
Модел маалыматыRXNG09AXVJU / FTXNG09AXVJU
BTU Capacity (Cooling)11 800 BTU (0.75 тонна)
BTU Capacity (Heating)4,400 BTU – 13,000 BTU
SEER2 Efficiency18 SEER2
Тtage208/230 Volts, 1 Phase, 60Hz
Ызы-чуу деңгээли (сырткы блок)56 дБ
Орнотуу түрүБөлүнүү тутуму
Форма факторуMini-Split
МуздаткычR 410A
Сунушталган камтуу аймагы400 чарчы футка чейин
Goodman Mini-Split AC/Heating System dimensions and specifications

Figure 4: Dimensional specifications and performance ratings for the Goodman Mini-Split AC/Heating System, including BTU, square footage coverage, and noise levels.

Кепилдик жана колдоо

For warranty information, please refer to the warranty card included with your product or visit the official ACiQ website. Warranty terms typically cover manufacturing defects and vary by component.

For technical support, service requests, or to inquire about replacement parts, please contact ACiQ customer service. Have your model number (RXNG09AXVJU / FTXNG09AXVJU) and purchase date ready when contacting support.

Онлайн ресурстар: For additional resources, FAQs, and product registration, visit the ACiQ Store on Amazon.

Тектеш документтер - RXNG09AXVJU / FTXNG09AXVJU

Preview ACiQ 9K-24K стандарттык жылуулук бир зона системалары: орнотуу жана ээсинин колдонмосу
ACiQ 9K-24K стандарттык жылуулук бир зона системаларын орнотуу жана ээсинин колдонмосу. Бул колдонмо ACiQ кондиционерлерин орнотуу, иштетүү, коопсуздук жана тейлөө, анын ичинде моделдин өзгөчөлүктөрүн жана R454B муздаткыч маалыматын камтыйт.
Preview ACiQ R32 көп зоналуу конденсатору жана дубалга орнотулган аба өткөргүчүнүн көйгөйлөрүн чечүү боюнча колдонмо
This troubleshooting guide provides detailed steps and solutions for common faults and errors encountered with ACiQ R32 Multi-Zone Condenser and Wall Mounted Air Handler systems, including sensor faults, communication errors, and component issues.
Preview ACiQ 9K-24K стандарттык жылуулук бир зона системалары: орнотуу жана ээсинин колдонмосу
ACiQ 9K-24K стандарттык бир зоналуу жылуулук системалары үчүн комплекстүү орнотуу жана ээсинин колдонмосу, ар кандай ACiQ моделдери үчүн орнотууну, иштетүүнү, тейлөөнү жана көйгөйлөрдү оңдоону камтыйт.
Preview ACiQ дубалга орнотулган аба иштеткич жана өтө ысык бир зоналуу конденсаторду орнотуу жана ээсинин колдонмосу
Бул колдонмо ACIQ-24ZPL-HP230C аркылуу ACIQ-06W-HH-MD моделдерин камтыган ACiQ дубалга орнотулган аба иштеткичтери жана өтө ысык бир зоналуу конденсаторлор үчүн деталдуу орнотуу, иштетүү жана коопсуздук эрежелерин камтыйт.
Preview ACiQ R32 көп зоналуу конденсатору жана дубалга орнотулган аба иштеткичтин тейлөө жана техникалык колдонмосу
Comprehensive service and technical manual for ACiQ R32 Multi-Zone Condenser and Wall Mounted Air Handler units. This guide provides detailed information on installation, operation, troubleshooting, and maintenance for models ACiQ-09W-E-M, ACiQ-12W-E-M, ACiQ-18W-E-M, ACiQ-18Z-E-M2, and ACiQ-24Z-E-M3.
Preview ACiQ Central Heat Pump Split System Owner's Manual & Operating Guide
Comprehensive owner's manual for ACiQ Central Heat Pump Split Systems, covering safety precautions, operating conditions, features, energy saving tips, care and maintenance, and troubleshooting for models ACiQ-24, ACiQ-36, and ACiQ-48.