This manual provides detailed instructions for the installation, operation, programming, and maintenance of the Alarm Lock DL270019 Trilogy T2 Stand Alone Digital Lock. This electronic cylindrical lock is designed for commercial, institutional, and indoor use, offering robust security and convenient access control.

The DL2700-19 features a vandal-proof all-metal keypad, multi-level user codes, and a durable design suitable for various applications including schools, healthcare facilities, pharmacies, rental properties, offices, retail environments, and airports.

2. Коопсуздук маалыматы

  • Орнотуудан жана колдонуудан мурун бардык нускамаларды кылдат окуп чыгыңыз.
  • Do not attempt to modify or disassemble the lock. This may void the warranty and compromise security.
  • Use only the specified battery type (5 AA Alkaline Batteries). Incorrect batteries may damage the device.
  • Keep the keypad clean and free from debris to ensure proper function.
  • Ensure all components are securely fastened during installation to prevent accidental injury or malfunction.

3. Пакеттин мазмуну

Орнотууну баштоодон мурун бардык компоненттер бар экендигин текшериңиз:

  • Alarm Lock DL270019 Trilogy T2 Digital Lock Assembly
  • 5 AA щелочтук батарейкалар
  • Screws for Wood/Metal Jambs
  • Installation Template (typically included, though not explicitly listed in provided data)
  • Колдонуучунун Колдонмосу (бул документ)

4. Орнотуу жана орнотуу

The DL2700-19 lock is designed for standard ANSI 161 Series door preparation and is non-handed, meaning it can be installed on left or right-hand doors without modification.

4.1 Эшик даярдоо

  • Ensure your door thickness is between 1-5/8 to 1-7/8 inches.
  • Verify the door is prepared for a standard ANSI 161 Series cylindrical lock.
  • The backset required is 2-3/4 inches.

4.2 Кулпуну орнотуу

  1. Install the latch assembly into the door edge. The latch throw is 1/2 inch.
  2. Install the strike plate (ASA or T Strike, 1-1/8" x 2-3/4" or 1-1/4" x 4-7/8") on the door frame using the provided screws.
  3. Mount the exterior and interior lock assemblies, ensuring proper alignment and cable connection.
  4. Secure the lock with the through-bolts and screws.

4.3 Батареяны орнотуу

The lock operates on 5 AA Alkaline Batteries. These are included with the product.

  1. Locate the battery compartment, typically on the interior side of the lock.
  2. Insert the 5 AA batteries, observing correct polarity (+/-).
  3. Батарея уясынын капкагын бекем жабыңыз.
Alarm Lock DL270019 Trilogy T2 Digital Lock, Matte Black finish

1-сүрөт: Alarm Lock DL270019 Trilogy T2 Digital Lock in Matte Black. This image shows the exterior keypad and lever assembly of the lock.

5. Иштөө нускамалары

5.1 Эшиктин кулпусун ачуу

  • Using a Code: Enter a valid user code on the keypad. The lock will emit an audible signal, and the outside lever will engage. Turn the lever to retract the latch and open the door.
  • Ачкычты колдонуу: Insert the Schlage C Series key into the cylinder and turn it to retract the latch.
  • Remote Bypass: If configured, a 2-wire remote override can be used to unlock the door.

5.2 Эшикти кулпулоо

The lock automatically re-locks after a short delay once the door is closed. The outside lever is free-turning when locked, preventing forced entry attempts by applying pressure to the lever.

5.3 Inside Egress

The inside lever provides instant egress at all times, allowing for immediate exit without requiring a code or key, even if the door is locked.

5.4 Батареянын төмөн көрсөткүчү

The lock features an audible low battery alert. When the batteries are low, the lock will emit a specific sound pattern to indicate that battery replacement is needed soon. Replace batteries promptly to ensure continuous operation.

6. Программалоо

The DL2700-19 supports up to 100 different multi-level user codes, including Master, Manager, User, and Service codes.

6.1 Master Code

The Master Code is used to access programming functions and manage other codes. It is recommended to change the default Master Code immediately after installation.

6.2 Manager Codes

Up to 10 Manager Codes can be programmed. Managers can add, delete, or modify User and Service codes, but cannot access Master programming functions.

6.3 Колдонуучу коддору

Up to 90 User Codes can be programmed for daily access. These codes only unlock the door and cannot access programming functions.

6.4 Кызмат коддору

Up to 3 Service Codes can be programmed. These are typically temporary codes for maintenance personnel or visitors, often with time-limited access.

6.5 Programmable Relay

The lock includes a programmable relay, which can be configured for various functions such as controlling an external alarm, door operator, or other security devices. Refer to the full programming guide (available online or with the product documentation) for detailed instructions on relay configuration.

For detailed programming steps for each code type and advanced features, please consult the comprehensive programming manual provided by Alarm Lock or visit their official support webсайт.

7. Техникалык тейлөө

7.1 Батареяны алмаштыруу

When the low battery indicator sounds, replace all 5 AA Alkaline Batteries promptly. Using fresh, high-quality alkaline batteries is recommended for optimal performance and battery life (approximately 200,000 cycles).

7.2 Тазалоо

Баскычтопту жана кулпу корпусун жумшак, damp Абразивдүү тазалоочу каражаттарды же эриткичтерди колдонбоңуз, анткени алар каптамага же электрондук компоненттерге зыян келтириши мүмкүн.

7.3 Key Cylinder Maintenance

Periodically lubricate the key cylinder with a graphite-based lubricant if the key becomes difficult to turn. Do not use oil-based lubricants.

8. Кыйынчылыктарды

КөйгөйМүмкүн себепЧечим
Кулпу баскычтоп жазуусуна жооп бербейт.Батареялар түгөнгөн; туура эмес код киргизилген; баскычтоптун иштебей калышы.Replace batteries; re-enter code carefully; contact support if issue persists.
Low battery alert sounds.Батареялары аз.Replace all 5 AA Alkaline Batteries immediately.
Lever turns but does not retract latch.Lock is in a locked state (outside lever free-turning); mechanical issue.Ensure a valid code or key is used to engage the clutch; inspect for obstructions or damage.
Жаңы коддорду программалоо мүмкүн эмес.Incorrect Master or Manager code used; programming sequence error.Verify Master/Manager code; review программалоо нускамаларын кылдаттык менен.

9. Техникалык шарттар

ӨзгөчөлүкДеталь
Продукт түрүElectronic Cylindrical Lock
Модель номериDL2700-19
БүтүрүүMatte Black (622/US19)
МатериалМеталл
БаскычтопVandal-Proof All Metal Keypad
Колдонуучунун коддору1 Master, 10 Managers, 90 Users, 3 Service Codes (Total 100)
Power Source5 AA щелочтук батарейкалар
Батареянын иштөө мөөнөтүБолжол менен 200,000 цикл
Эшиктин калыңдыгы1-5/8ден 1-7/8 дюймга чейин
Backset2-3/4 дюйм
Latch Throw1/2 дюйм
Иш таштоо түрүASA; T Strike
KeywaySchlage C Series
БерүүКол менен эмес
Иштөө температурасы-31…151°F (-35…66°C)
СтандарттарBHMA Certified, UL Listed, FCC Certified, ANSI/BHMA Grade 1
ADA менен шайкешОоба
Өлчөмдөрү (L x W x Y)4 x 2 x 9 дюйм
Элемент Салмагы9 фунт

10. Кепилдик жана колдоо

10.1 Кепилдик маалыматы

The Alarm Lock DL270019 Trilogy T2 Digital Lock comes with a 2 жылдык кепилдик сатып алынган күндөн тартып. Бул кепилдик нормалдуу колдонуудагы материалдардагы жана жасалгадагы кемчиликтерди камтыйт. Кепилдик дооматтары үчүн сатып алганыңыздын далилин сактап коюңуз.

The warranty does not cover damage resulting from improper installation, misuse, abuse, unauthorized modification, or natural disasters.