1. Киришүү
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Goodman 2 Ton 13.4 SEER2 R-32 AC Only System. This system comprises the Goodman GLXS3BN2410 Air Conditioner (condenser) and the CAPTA2422A3 vertical coil. Please read this manual thoroughly before proceeding with any procedures.

Figure 1: Goodman 2 Ton AC Only System (Condenser and Vertical Coil)
2. System Setup and Compatibility
The Goodman 2 Ton 13.4 SEER2 AC Only System is designed for efficient cooling. It requires a compatible furnace or modular blower to form a complete operational system. This system utilizes R-32 refrigerant, which has specific handling and safety requirements.
2.1 R-32 Refrigerant Considerations
R-32 refrigerant is more energy-efficient and has a lower global warming impact compared to older refrigerants like R-410A. However, R-32 is slightly flammable. Therefore, if this system is used in conjunction with a furnace, an R-32 leak detection system is required for safe operation. This system will communicate with the furnace to shut off the burner if a refrigerant leak is detected, preventing ignition risks.
Video 1: Information about R-32 Refrigerant Regulations
Video 2: R-32 Fact vs Fiction (Preview)
2.2 Компонентти алмаштыруу
When upgrading or replacing an existing system, it is crucial to understand that R-410A and R-32 refrigerants are not backwards compatible. If you are replacing either the outdoor condenser or the indoor coil, you must replace both components to ensure compatibility and proper system function. Attempting to mix components designed for different refrigerants will lead to system failure and potential safety hazards.
Video 3: Condenser with Coil Combination
2.3 Системанын конфигурациясы
The indoor coil (CAPTA2422A3) is a vertical coil design, which streamlines airflow. Ensure your existing or new furnace/blower is compatible with a vertical coil configuration. Common configurations include upflow (air enters from bottom, exits top) or downflow (air enters from top, exits bottom). Verify your system's airflow direction to ensure proper installation.
Video 4: What Type of System Do You Have?
2.4 Fuel Type (Furnace)
If pairing with a gas furnace, most furnaces are sold for natural gas. If your home uses liquid propane (LP), a separate LP conversion kit will be required for the furnace. Consult your furnace manual for specific conversion requirements.
Video 5: AC with Furnace Systems
3. Системаны иштетүү
Your Goodman AC Only System is designed for user-friendliness and efficient cooling. Once properly installed and connected to a compatible furnace/blower and thermostat, operate the system according to your thermostat's instructions.
3.1 Efficiency and Noise
This system boasts a 13.4 SEER2 rating, indicating high energy efficiency. The noise level is rated at 74 Decibels. The SEER2 rating reflects updated testing protocols by the U.S. Department of Energy to ensure more accurate real-world performance.

Figure 2: EnergyGuide Label for GLXS3BN2410 Condenser
Video 6: SEER2 Regulations - 01
Video 7: SEER2 Regulations - 02
4. Техникалык тейлөө
Regular maintenance is essential to ensure the longevity and optimal performance of your Goodman AC Only System. It is recommended to have a qualified HVAC technician perform annual inspections and servicing.
4.1 Колдонуучуну тейлөө
- Аба чыпкасын алмаштыруу: Regularly check and replace the air filter in your furnace/blower unit as recommended by the manufacturer. A clean filter ensures proper airflow and system efficiency.
- Ачык сырткы блок: Keep the area around the outdoor condenser unit clear of debris, leaves, and other obstructions to ensure proper airflow.
4.2 Кесиптик тейлөө
- Катушканы тазалоо: The indoor and outdoor coils should be professionally cleaned to maintain heat transfer efficiency.
- Refrigerant Level Check: A technician can verify the correct refrigerant charge.
- Электр байланыштары: All electrical connections should be inspected for tightness and wear.
- Дренаж системасы: The condensate drain line should be checked for clogs.
5. Кыйынчылыктарды
If your system is not operating correctly, consider the following basic troubleshooting steps before contacting a service technician:
- Муздатуу жок: Check your thermostat settings to ensure it is set to 'Cool' mode and the temperature is below the current room temperature. Verify that the circuit breaker for the outdoor unit and indoor unit has not tripped.
- Начар аба агымы: Check the air filter for excessive dirt and replace if necessary. Ensure all supply and return vents are open and unobstructed.
- адаттан тыш үндөр: Minor operational noises are normal. However, if you hear loud or unusual sounds, turn off the system and contact a qualified technician.
- R-32 Leak Detection: If your system is equipped with an R-32 leak detection system and it triggers a furnace shutdown, contact a qualified HVAC technician immediately to address the leak and ensure safety.
For any issues beyond basic troubleshooting, it is highly recommended to contact a certified HVAC professional for diagnosis and repair.
6. Техникалык шарттар
| Өзгөчөлүк | Деталь |
|---|---|
| Бренд аты | Гудман |
| Модел маалыматы | GLXS3BN2410CAPTA2422A3 |
| Элемент Салмагы | 151 фунт |
| Натыйжалуулук | Жогорку натыйжалуулук |
| Кубаттуулугу | 2 тонна |
| Ызы-чуу деңгээли | 74 децибел |
| Орнотуу түрү | Бөлүнүү тутуму |
| Бөлүмдүн номери | GLXS3BN2410CAPTA2422A3 |
| Форма фактору | Split-система |
| Өзгөчөлүктөр | Energy Efficient Compressor, Maximized Efficiency Coils, Corrosion Prevention, Durable Construction, Advanced Coil Design, Factory-Installed Expansion Valve, R-32 Refrigerant Compatibility |
| Тtage | 230 вольт |
| Муздатуу күчү | 24000 Британиянын жылуулук бирдиктери |
| BEE Star Rating | 4 Star |
| Сезондук энергияны натыйжалуулук коэффициенти (SEER) | 13.4 |
| Муздаткыч | R-32 |
| Power Source | Электр зымдары |
| Дата биринчи жеткиликтүү | 27-август, 2024-жыл |
7. Кепилдик жана колдоо
Your Goodman AC Only System is backed by a reassuring 10-year parts warranty. For specific warranty details and to register your product, please refer to the documentation included with your purchase or visit the official Goodman webсайт.

Figure 3: Goodman System Overview with 10-Year Parts Warranty
7.1 Кардарларды колдоо
For technical assistance, service inquiries, or any questions regarding your Goodman product, please contact Goodman customer support. Contact information can typically be found on the product packaging or the official Goodman webсайт.





