This manual provides essential information for the safe and efficient installation, operation, and maintenance of your ACiQ 1.5 Ton 16 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before attempting any procedures. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

Сүрөт 1.1: Бүттүview of the ACiQ 1.5 Ton Central Air Conditioner System and included installation kit.
2. Коопсуздук маалыматы
WARNING: Installation and servicing of this equipment can be hazardous due to system pressure, electrical components, and sharp edges. Only qualified, trained, and licensed HVAC technicians should install, repair, or service this equipment. Failure to follow this warning could result in property damage, personal injury, or death.
- Кандайдыр бир тейлөөнү же тейлөөнү аткаруудан мурун, ар дайым блокту электр кубатынан ажыратыңыз.
- Тиешелүү жеке коргонуу шаймандарын (ЖКК), анын ичинде кол каптарды жана көздү коргоону кийиңиз.
- Бардык электр тетиктерин туура жерге туташтырууну камсыз кылыңыз.
- Do not operate the unit with damaged electrical cords or components.
- Иштөө жана тейлөө учурунда балдарды жана үй жаныбарларын блоктон алыс кармаңыз.
3. Пакеттин мазмуну
Төмөндө тизмеленген бардык компоненттер пакетиңизде бар экенин текшериңиз:
- Сырткы конденсатор блогу
- Indoor Evaporator Cased Coil (Multi-Positional)
- Smart WiFi термостат
- 30' изоляцияланган линия топтому (3/8" узундук x 3/4" узундук x 3/8")
- 1/2" x 6' 10 калибрлүү электр камчысы
- 60A Эриткичсиз ажыратуу которгучу
- Чыңалуудан коргоочуну башкарат
- CPS кубаттоочу адаптер
- Wall Sleeve
- Дубалга орнотуу кронштейн
- Колдонуучунун Колдонмосу (бул документ)

Image 3.1: Components included in the ACiQ Split System Installation Kit.
4. Продукт бүтүп калдыview жана өзгөчөлүктөрү
4.1. Inverter AC Technology
The ACiQ system utilizes inverter technology, which allows the compressor to adjust its speed continuously. This precise control maintains a consistent indoor temperature, reduces energy consumption, and results in quieter operation compared to traditional single-stage системалары.
4.2. Multi-Positional Evaporator Cased Coil
The included cased coil is designed for multi-positional installation, offering flexibility for various HVAC system configurations. It features a factory-integrated TXV (Thermostatic Expansion Valve) for optimized refrigerant flow and enhanced system efficiency.
4.3. Smart Thermostat
The system comes with a Smart WiFi Thermostat, enabling remote control and advanced scheduling features. It integrates with popular smart home platforms for convenient management of your home's climate.

Image 4.1: Key features of the ACiQ Air Conditioner, including inverter technology, gold fin coil, and quiet operation.

Image 4.2: Detailed features and interface of the included Smart Thermostat.
5. Техникалык шарттар
| Спецификация | Нарк |
|---|---|
| Бренд аты | ACiQ |
| Модел маалыматы | ACiQ-18-AC / ACIQ-24-ACL / IKIC31 |
| Кубаттуулугу | 1.5 тонна (42 000 BTU/саат) |
| SEER2 рейтинги | 16.8ге чейин |
| Тtage | 230 вольт |
| Ватtage | 1538 ватт |
| Орнотуу түрү | Бөлүнүү тутуму |
| Форма фактору | Борбордук сплит системасы |
| Өзгөчөлүктөр | Инвертордук блок, акылдуу сенсорлор, алтын түстүү спираль, өтө тынч, бардык климаттык шарттарга жооп берет |
| Полдун аянты | 900 чарчы футка чейин |
| Outdoor Condenser Dimensions (D x W x H) | 13.46 x 35.04 x 26.5 дюйм |
| Бууланткычтын катушкасынын өлчөмдөрү (туурасы x тереңдиги x бийиктиги) | 17.52 x 20.98 x 17.99 дюйм |
| Evaporator Coil Air Flow | 720.04 CFM |
| Evaporator Coil Dehumidification | 3.02 |

Image 5.1: Dimensional measurements for the ACiQ outdoor condenser and evaporator coil.

Image 5.2: Detailed specifications for the ACiQ evaporator coil.
6. Орнотуу жана орнотуу
IMPORTANT: This ACiQ Central Air Conditioner System requires professional installation by a qualified and licensed HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, voided warranty, and improper operation.
6.1. Орнотууга чейинки текшерүүлөр
- Ensure the installation site meets local building codes and regulations.
- Verify that the electrical supply matches the unit's requirements (230 Volts).
- Confirm adequate space for both the outdoor condenser and indoor evaporator coil, allowing for proper airflow and service access.
6.2. Орнотуу кадамдары (ашыкview Техник үчүн)
- Mounting the Outdoor Condenser: Securely mount the outdoor unit using the provided wall mount bracket or a suitable ground-level pad, ensuring proper drainage and vibration isolation.
- Installing the Indoor Evaporator Coil: Integrate the multi-positional cased coil with your existing furnace or air handler, ensuring proper sealing and airflow.
- Connecting Refrigerant Lines: Connect the insulated line set between the outdoor and indoor units. This involves brazing and vacuuming the lines to remove moisture and non-condensable gases, followed by charging with R410A refrigerant.
- Электр зымдары: Connect the electrical whip, disconnect switch, and controls surge protector according to wiring diagrams provided with the unit and local electrical codes. Connect the smart thermostat.
- System Start-up and Testing: Perform a leak check, verify proper refrigerant charge, test all operational modes, and calibrate the thermostat.
7. Иштөө нускамалары
Once professionally installed, your ACiQ system is designed for user-friendly operation primarily through the Smart WiFi Thermostat.
7.1. Smart Thermostat Operation
Refer to the separate Smart WiFi Thermostat manual for detailed instructions on its features, including:
- Setting desired temperature (cooling/heating set points).
- Selecting operating modes (Cool, Heat, Auto, Fan Only).
- Programming schedules and presets.
- Connecting to your home's WiFi network for remote access via a mobile application.
- Integration with voice assistants (e.g., Alexa, Google Assistant) and smart home platforms (e.g., SmartThings, IFTTT).
7.2. Inverter Technology Benefits
The inverter system automatically adjusts its output to match the cooling demand, providing consistent comfort and energy savings. You may notice the compressor running at varying speeds, which is normal operation for an inverter unit.
8. Техникалык тейлөө
Regular maintenance ensures the efficiency and longevity of your ACiQ system. Some tasks can be performed by the homeowner, while others require a professional technician.
8.1. Колдонуучуну тейлөө
- Аба чыпкаларын тазалоо же алмаштыруу: Check your furnace/air handler's air filter monthly and clean or replace it as needed. A dirty filter restricts airflow and reduces efficiency. The system uses a washable, reusable mesh filter.
- Ачык сырткы блок: Keep the area around the outdoor condenser unit free from debris, leaves, and vegetation to ensure proper airflow.
- Clean Evaporator Coil Drain Pan: Periodically check and clean the condensate drain pan to prevent clogs and water overflow.
8.2. Кесиптик техникалык тейлөө
Schedule annual maintenance with a qualified HVAC technician. This typically includes:
- Муздаткычтын деңгээлин жана басымын текшерүү.
- Cleaning condenser and evaporator coils.
- Электр туташууларын жана компоненттерин текшерүү.
- Кыймылдуу бөлүктөрүн майлоо (эгер бар болсо).
- Термостатты калибрлөөнү текшерүү.
- Агып кетүүлөрдү текшерүү үчүн аба өткөргүчтөрдү текшерүү.
9. Кыйынчылыктарды
Кызматка чакыруудан мурун, кайраview бул жалпы маселелер жана чечимдер:
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Система муздатпайт/жылытпайт | Thermostat setting incorrect, dirty air filter, power supply issue, tripped breaker. | Check thermostat settings, replace/clean filter, check circuit breaker, ensure power is on. |
| Начар аба агымы | Dirty air filter, blocked vents, obstructed outdoor unit. | Clean/replace filter, ensure vents are open, clear debris from outdoor unit. |
| адаттан тыш үндөр | Loose parts, debris in fan, refrigerant issues. | Inspect for loose panels or debris. If persistent, contact a technician. |
| Суунун агып чыгышы | Clogged condensate drain line, frozen evaporator coil. | Clear drain line. If coil is frozen, turn off unit and contact a technician. |
If these steps do not resolve the issue, contact a qualified HVAC technician for further diagnosis and repair.
10. Кепилдик жана колдоо
10.1. Кепилдик шарттары
Your ACiQ Central Air Conditioner System comes with a warranty of бөлүктөрү боюнча 7 жыл жана Компрессордо 12 жыл иштеген. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please retain your proof of purchase and installation records.
10.2. Кардарларды колдоо кызматы
For technical assistance, warranty claims, or to locate a certified service provider, please visit the official ACiQ website or contact their customer support line. (Specific contact details are typically provided on the manufacturer's website or warranty card.)
11. AHRI Rating Conditions
AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification is essential for HVAC units as it assures performance, energy efficiency, quality, regulatory compliance, and provides benefits like market differentiation, financial incentives, and consumer protection.

Image 11.1: AHRI Certification and EnergyGuide label details for the ACiQ system, showing SEER2 rating and cooling capacity.
The manufacturer of this ACiQ product is responsible for the rating of this system combination. The unit is rated as follows in accordance with the latest edition of AHRI 210/240-2024, Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment:
- AHRI Certified Number: 214731227
- Дата: 08-26-2024
- Model Status: Активдүү
- AHRI Type: RCU-A-C (Split System: Air-Cooled Condensing Unit, Coil Alone)
- Бренд аты: ACiQ
- Сырткы блок: ACiQ-18-AC
- Ички блок: ACiQ-24-ACL
- Cooling Capacity BTU/h: 18000
- SEER2: 16.00
- EER2 Single or High Stage: 11.70