Thank you for choosing the HBN 60-Minute Spring Wound Countdown Timer Switch. This in-wall mechanical timer is designed to automatically turn off connected lights or appliances after a user-defined period, up to 60 minutes. It promotes energy efficiency by preventing devices from being left on unintentionally, making it ideal for various applications in homes, offices, and workshops.
Негизги өзгөчөлүктөрү:
- Energy-Saving Automatic Shut-Off: Automatically powers off devices after a set time, reducing energy waste.
- Жөнөкөй операция: Features a spring-wound twist mechanical knob for intuitive time setting.
- Оңой орнотуу: No neutral wire required, simplifying the installation process in standard electrical boxes.
- Ар тараптуу колдонмолор: Suitable for bathroom fans, lights, space heaters, and various small appliances.
2. Коопсуздук маалыматы
WARNING: RISK OF ELECTRIC SHOCK. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker before installation. If you are unsure about any part of these instructions, consult a qualified electrician.
- Бул түзмөк Улуттук электр кодексине жана жергиликтүү эрежелерге ылайык орнотуу үчүн арналган.
- Ensure the power supply is disconnected at the circuit breaker or fuse box before attempting installation or maintenance.
- Do not use this timer with devices that could cause hazardous conditions if left unattended, such as sunlamps, saunas, or similar equipment.
- The timer is ETL Listed, indicating compliance with recognized safety standards.
3. Пакеттин мазмуну
Орнотууну баштоодон мурун бардык компоненттер бар экендигин текшериңиз:
- HBN 60-Minute Spring Wound Countdown Timer Switch
- Дубал плитасы
- Wire Nuts (Connecting Terminals)
- Монтаждоо бурамалар

Сүрөт 3.1: Contents of the HBN 60-Minute Spring Wound Countdown Timer Switch package, including the timer switch, wall plate, wire nuts, and mounting screws.
4. Техникалык шарттар
| Параметр | Нарк |
|---|---|
| Модел | B0DHCPLG51 |
| Иштөө режими | КҮЙГҮЗҮҮ ӨЧҮРҮҮ |
| Учурдагы рейтинг | 20 Amps |
| Operating Voltage | 125 Вольт |
| Жыштык | 60 Гц |
| Резистивдик жүк | 20А / 2500 Вт |
| Вольфрам жүк | 8А / 1000 Вт |
| Балласт жүк | 5А / 625 Вт |
| Мотор жүк | 1 HP |
| Circuit Type | 1-жол |
| Актуатор түрү | Айлануучу баскыч |
| Сертификаттар | ETL тизмеленген |
| Продукциянын өлчөмдөрү (L x W x Y) | 4.09 x 1.57 x 1.34 дюйм |
| Салмагы | 5.61 унция |

Сүрөт 4.1: Detailed dimensions of the HBN 60-Minute Spring Wound Countdown Timer Switch and its wall plate.
5. Орнотуу
This timer switch is designed for easy installation and does not require a neutral wire. It can replace most standard light switches.
Керектүү куралдар:
- Бурагыч (Phillips жана/же Flathead)
- Wire Strippers (if needed)
- Электр лентасы (милдеттүү эмес)
- Тtage Сыноочу (сунушталат)
Орнотуу кадамдары:
- Кубатты өчүрүү: Locate the circuit breaker that controls the switch you are replacing and turn it OFF. Verify power is off using a voltage сыноочу.
- Эски которгучту алып салуу: Unscrew and carefully remove the existing wall plate and switch from the electrical box.
- Зымдарды аныктоо: The HBN timer switch requires two wires: a Hot wire and a Load wire. These are typically the two wires connected to your old switch. This timer does not require a neutral wire or a ground wire for operation.
- Зымдарды туташтыруу: Using the provided wire nuts, connect the wires from the electrical box to the corresponding wires on the HBN timer switch.
- туташтыруу Ысык wire from the electrical box to one of the timer's wires.
- туташтыруу Жүктөө wire (leading to the light/appliance) from the electrical box to the other timer wire.

Сүрөт 5.1: Wiring diagram illustrating the connection of the HBN timer switch to Hot and Load wires. No neutral or ground wire connection is required.
- Которгучту орнотуу: Carefully push the connected wires back into the electrical box. Secure the timer switch to the electrical box using the provided mounting screws.
- Дубал плитасын орнотуу: Attach the new wall plate over the timer switch and secure it with its screws.
- Күчтү калыбына келтирүү: Электрди өчүргүчтөн кайра күйгүзүңүз.
Compatibility with Existing Wall Plates:
The HBN timer switch is designed to fit various standard wall plate configurations, including single-gang decorator, multi-gang standard, and decorator/toggle combination plates.

Сүрөт 5.2: Examples of how the HBN timer switch can be integrated into different wall plate setups, demonstrating its universal fit.
6. Операция
Operating the HBN 60-Minute Spring Wound Countdown Timer Switch is straightforward:
- Таймерди коюу: To activate the timer, rotate the knob clockwise past the 10-minute mark, then turn it back counter-clockwise to your desired countdown duration (from 1 to 60 minutes). The device will remain ON for the set duration and then automatically turn OFF.
- Turn OFF Manually: To turn off the connected device before the countdown completes, rotate the knob counter-clockwise until it reaches the "OFF" position.

Сүрөт 6.1: Illustration of turning the dial on the HBN timer switch to set the desired countdown time, up to 60 minutes.
Тиркемелер:
This timer is suitable for a wide range of applications, including:
- Bathroom exhaust fans
- Bedroom lights
- Closet lights
- Laundry room lighting
- Space heaters (within specified load limits)
- Aquarium lights
- Other small appliances

Сүрөт 6.2: Визуалдык эксamples of the HBN timer switch being used in various household settings such as bathrooms, living rooms, laundry rooms, and closets.
7. Техникалык тейлөө
The HBN 60-Minute Spring Wound Countdown Timer Switch requires minimal maintenance.
- Тазалоо: To clean the switch and wall plate, wipe with a soft, damp кездеме. Абразивдүү тазалагычтарды же эриткичтерди колдонбоңуз. Тазалоодон мурун электр кубаты өчүрүлгөнүн текшериңиз.
- Текшерүү: Periodically inspect the switch for any signs of damage or loose connections. If any issues are found, turn off power and address them immediately.
- Нымдуулуктан качыңыз: Do not expose the switch to excessive moisture or direct water spray.
8. Кыйынчылыктарды
If you encounter issues with your HBN timer switch, refer to the following common problems and solutions:
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Device does not turn ON or OFF. | No power to the switch; incorrect wiring; faulty switch. | Check circuit breaker. Verify wiring connections are secure and correct (Hot and Load). If issues persist, the switch may be faulty. |
| Timer does not count down or stops prematurely. | Timer not wound sufficiently; internal mechanism issue. | Ensure the knob is rotated clockwise past the 10-minute mark before setting the desired time. If the problem continues, contact support. |
| Timer turns OFF but then restarts or does not stay OFF when set to 'OFF'. | Knob not fully rotated to the 'OFF' position; internal mechanism issue. | Ensure the knob is firmly rotated counter-clockwise to the designated 'OFF' position. The timer should not tick when in the 'OFF' position. If it continues to tick or restart, contact support. |
| Loud ticking sound during operation. | Normal operation for a mechanical spring-wound timer. | A slight ticking sound is characteristic of mechanical timers as the spring unwinds. This is generally not an indication of a fault. |
9. Кепилдик жана колдоо