1. Киришүү
The Victron Energy Lynx Smart BMS NG 500A is an advanced Battery Management System designed for Victron Energy Lithium NG batteries. It is an integral component of the modular Lynx Distribution system, ensuring optimal safety, seamless performance, and efficient monitoring for Lithium NG battery banks. This model is specifically the 500A variant, suitable for various capacities of 12.8V, 25.6V, and 51.2V Lithium NG batteries.

Image: The Victron Energy Lynx Smart BMS NG 500A unit, featuring its blue casing, connection points, and branding.
2. Коопсуздук маалыматы
Always adhere to the following safety guidelines during installation, operation, and maintenance of the Lynx Smart BMS NG 500A:
- Орнотуу квалификациялуу кызматкерлер тарабынан гана аткарылышы керек.
- Орнотуудан же тейлөөдөн мурун бардык кубат булактары ажыратылганын текшериңиз.
- Wear appropriate personal protective equipment (PPE), including eye protection and insulated gloves.
- Аппаратты экстремалдык температурага же түз күн нуруна узак убакытка калтырбаңыз.
- Verify correct polarity for all connections to prevent damage to the unit and connected equipment.
- Refer to the full safety manual for comprehensive safety instructions.
3. Продукциянын өзгөчөлүктөрү
The Lynx Smart BMS NG 500A offers several key features for robust battery management:
- Built-in 500A Contactor: Provides essential fallback safety and enables remote-controlled main system switching.
- Батарея мониторинги: Displays the state of charge and other vital data for efficient system management.
- Pre-Alarm Signal: Alerts users before a system shutdown occurs due to low cell voltage, allowing for timely intervention.
- Bluetooth байланышы: Facilitates easy setup, monitoring, and diagnosis of the system via the VictronConnect App.
- M10 Busbar Integration: Ensures seamless connection to all Lynx M10 products, integrating smoothly into the Lynx Distributor system.
4. Орнотуу жана орнотуу
The Lynx Smart BMS NG 500A is designed for straightforward integration into your power system. It features M10 Busbar Integration for seamless connection with other Lynx M10 components. The unit is also designed with a high level of ingress protection (IP65), making it suitable for installation in various environments, including those exposed to dust and water splashes.
The cables for auxiliary connections are resin-bonded to the device, enhancing durability and protection against environmental factors. This design simplifies wiring and ensures a secure connection.
Video: This video demonstrates the features of the SmartShunt IP65, including its high ingress protection and pre-attached cables, which are similar design principles applied to the Lynx Smart BMS NG for enhanced durability and ease of installation.
For detailed wiring diagrams and specific installation steps, refer to the comprehensive installation guide provided with your product or available on the Victron Energy webсайт.
5. Системаны иштетүү
The Lynx Smart BMS NG 500A is operated and monitored primarily through the VictronConnect App and the Victron Remote Management (VRM) portal. These tools provide comprehensive control and visibility over your battery system.
5.1. VictronConnect колдонмосу
The VictronConnect App allows you to connect to your BMS via Bluetooth for local monitoring and configuration. You can view real-time data, adjust settings, and perform firmware updates directly from your smartphone or tablet.
Video: This video illustrates how the VictronConnect App can be used to monitor the performance of Victron Energy devices, including battery management systems, providing key data and control options.
Key functions available through the app include:
- Viewing battery state of charge, voltagд, ток жана температура.
- Accessing historical data and trends over time.
- Configuring battery presets and other operational parameters.
- Performing firmware updates for your device.
5.2. Victron Remote Management (VRM) Portal
For remote monitoring and management of your system, the VRM portal provides a comprehensive online platform. This allows you to check the status of your system from anywhere with an internet connection, manage devices, and set up alerts.
Видео: Бул видеодо толук маалымат берилетview of the Victron Remote Management (VRM) portal, showcasing its capabilities for monitoring and managing Victron Energy systems remotely, including alerts and performance tracking.
The VRM portal enables:
- Remote monitoring of system performance and historical data.
- Management of multiple Victron Energy installations.
- Configuration of programmable alerts and alarms for critical events, such as low cell voltage.
6. Техникалык тейлөө
Regular maintenance ensures the longevity and optimal performance of your Lynx Smart BMS NG 500A. Perform the following checks periodically:
- Визуалдык текшерүү: Check for any signs of physical damage, loose connections, or corrosion on the unit and cables.
- Программалык камсыздоонун жаңыртуулары: Regularly check for and install the latest firmware updates via the VictronConnect App to ensure optimal functionality and security.
- Туташуу бүтүндүгү: Бардык электр байланыштары бекем жана коопсуз экендигин текшериңиз.
- Тазалоо: Keep the unit clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.
7. Кыйынчылыктарды
If you encounter issues with your Lynx Smart BMS NG 500A, consider the following troubleshooting steps:
- Кубат жок: Verify all power connections and check for blown fuses in the system. Ensure the battery bank is adequately charged.
- Communication Issues (Bluetooth/VRM):
- Ensure Bluetooth is enabled on your device and the VictronConnect App is updated.
- Check the distance between your device and the BMS; Bluetooth range may be limited.
- For VRM, verify internet connectivity and proper configuration of your GX device (if applicable).
- Pre-Alarm Signal: If a pre-alarm signal is active, check the battery voltage and state of charge immediately. Reduce load or initiate charging to prevent system shutdown.
- Системаны өчүрүү: If the system has shut down, identify the cause (e.g., low voltage, overcurrent) using the VictronConnect App or VRM portal. Address the underlying issue before attempting to restart the system.
- Документацияны караңыз: Refer to the detailed troubleshooting section in the full product manual for more specific scenarios and solutions.
8. Техникалык шарттар
| Өзгөчөлүк | Нарк |
|---|---|
| Модел | Lynx Smart BMS NG 500A |
| Бренд | VictronEnergy |
| Учурдагы рейтинг | 500 Amps |
| Output Voltage | 60 вольт (ток) |
| Пакеттин өлчөмдөрү | 12.5 x 8 x 4 дюйм |
| Элемент Салмагы | 5.15 фунт |
| Камтылган компоненттер | 1 Батареяны башкаруу системасы |
| Батареялар талап кылынат | Жок |
9. Кепилдик жана колдоо
Victron Energy products are designed for reliability and performance. For warranty information, please refer to the official Victron Energy warranty policy available on their webсайт. Ар кандай кепилдик дооматтары үчүн сатып алганыңыздын далилин сактаңыз.
For technical support, product inquiries, or assistance with installation and troubleshooting, please contact Victron Energy customer support or visit their official support pages. Authorized dealers and service centers can also provide expert assistance.
Онлайн ресурстар:
- Расмий Victron Energy Webсайт: www.victronenergy.com
- VictronConnect App: Available on iOS and Android app stores.
- VRM Portal: vrm.victronenergy.com