Introduction
Thank you for choosing the CARRE Manual Hospital Bed, Model CCH-001. This bed is designed to provide comfort and support for patients in home, hospital, or medical care settings. Featuring a robust iron and ABS construction, it offers a high weight capacity and manual adjustments for backrest and leg rest positions. This manual provides essential information for safe assembly, operation, maintenance, and troubleshooting.
Маанилүү коопсуздук маалыматы
Please read all safety warnings and instructions carefully before assembling or operating the bed. Failure to do so may result in injury or damage to the product.
- Максималдуу Салмак сыйымдуулугу: Do not exceed the maximum load capacity of 200 kg (440 lbs). Exceeding this limit can compromise patient safety and bed stability.
- Чогултуу жана колдонуу: Ensure all assembly and usage instructions are followed correctly to guarantee the safety of both the patient and the user.
- Professional Supervision: In hospital or medical settings, use this bed only under the supervision of a healthcare professional.
- Тормоз системасы: Always engage the wheel braking system when the bed is stationary to prevent unintended movement.
- Каптал рельстер: Ensure side rails are securely locked in place when raised to prevent falls.
- Тазалоо: Ensure adequate clearance around the bed when adjusting positions to prevent pinching or crushing injuries.
Орнотуу жана чогултуу
The CARRE Manual Hospital Bed requires assembly. It is recommended that two people assemble the bed for ease and safety.
Пакеттин мазмуну:
- Bed Frame Components (Headboard, Footboard, Bed Base)
- Каптал рельстер
- Manual Cranks (2)
- Wheels with Brakes (4)
- IV полюс
- Матрас
- Overbed Table (Bridge Table)
- Монтаждоочу жабдуулар (болт, гайкалар, шайбалар, ачкычтар)
Чогултуу кадамдары:
- Компоненттерди таңгактан чыгаруу: Carefully remove all parts from the packaging and lay them out on a clean, flat surface. Verify all components are present against the package contents list.
- Дөңгөлөктөрдү тиркөө: Securely attach the four wheels to the bed frame legs. Ensure the braking mechanism on each wheel is functional.
- Assemble Bed Base: Connect the main bed base sections. Follow the diagrams provided in the separate assembly guide (if applicable) to ensure correct alignment and secure fastening of all bolts.
- Install Headboard and Footboard: Attach the headboard and footboard to the assembled bed base. Ensure they are firmly secured.
- Mount Side Rails: Install the foldable side rails onto the designated points on the bed frame. Test their locking mechanism to ensure they can be securely raised and lowered.
- Attach Manual Cranks: Insert the two manual cranks into their respective slots for backrest and leg rest adjustment.
- Орун матрасы: Lay the mattress onto the bed base.
- Install IV Pole: Insert the IV pole into the designated receptacle on the bed frame.
- Position Overbed Table: Place the overbed table as needed for patient use.
- Акыркы текшерүү: Before first use, double-check all connections, bolts, and mechanisms to ensure they are secure and functioning correctly.

Figure 1: Fully assembled CARRE Manual Hospital Bed, showing the bed frame, mattress, and IV pole. An inset image shows a patient comfortably using the bed with an overbed table.
Иштөө нускамалары
Төшөктүн орундарын тууралоо:
The CARRE Manual Hospital Bed features two manual cranks for adjusting the backrest and leg rest sections.

Figure 2: The dual manual cranks located at the foot end of the bed, used for adjusting the backrest and leg rest.
- Артканы тууралоо: Locate the crank responsible for the backrest (typically the one closer to the head of the bed). Turn the crank clockwise to raise the backrest and counter-clockwise to lower it. The backrest can be elevated up to 85 degrees for patient comfort, reading, or eating.
- Бут эс алуу тууралоо: Locate the crank responsible for the leg rest (typically the one closer to the foot of the bed). Turn the crank clockwise to raise the leg rest and counter-clockwise to lower it. The leg rest can be elevated up to 45 degrees to reduce leg pain or pressure.
- Combined Adjustment: Both the backrest and leg rest can be adjusted independently or in combination to achieve various comfortable and therapeutic positions.

Figure 3: The bed with its backrest adjusted to an elevated position, providing support for the patient's upper body.

Figure 4: The bed with its leg rest adjusted to an elevated position, designed to alleviate leg discomfort and improve circulation.

Figure 5: The bed demonstrating both backrest and leg rest elevated, providing a reclined position for patient comfort.
Using the Wheels and Brakes:
The bed is equipped with silent wheels for easy movement and a braking system for stability.
- Төшөктү жылдыруу: To move the bed, ensure all four wheel brakes are disengaged. Gently push the bed in the desired direction.
- Тормоздорду иштетүү: To secure the bed in place, push down on the lever located on each wheel until it clicks into the locked position. This prevents the bed from rolling.
- Disengaging Brakes: To unlock the wheels, lift the lever on each wheel until it clicks into the unlocked position.

Figure 6: Detail of a bed wheel with its brake mechanism, and the secure locking mechanism for the side rail.
Using the Side Rails:
The bed features foldable side rails for patient safety and ease of access.
- Raising Side Rails: Lift the side rail upwards until it locks securely into the raised position. Ensure the locking mechanism is fully engaged.
- Lowering Side Rails: Locate the release lever or button on the side rail (as shown in Figure 6). Press or pull the lever/button and gently lower the rail. Ensure it is fully lowered for patient entry/exit or care.

Figure 7: Detail of the foldable side rails, designed for patient safety and easy access for caregivers.
Using the IV Pole:
The bed includes a removable IV pole for medical treatments.
- Орнотуу: Insert the base of the IV pole into the designated receptacle on the bed frame, typically near the headboard.
- Жөнгө салуу: The IV pole's height can be adjusted by loosening the locking collar, extending or retracting the pole, and then tightening the collar to secure it at the desired height.
- Алып салуу: To remove, loosen the locking collar (if applicable) and lift the pole out of its receptacle.

Figure 8: The hospital bed with the IV pole attached, ready for use with medical infusions.
Техникалык тейлөө жана кам көрүү
Regular maintenance ensures the longevity and safe operation of your CARRE Manual Hospital Bed.
- Bed Structure Cleaning: Clean the bed frame structure with a dry cloth. For stains, use a damp жумшак самын менен сүртүңүз. Абразивдүү тазалоочу каражаттардан же катуу химиялык заттардан алыс болуңуз.
- ABS Parts Cleaning: Clean ABS plastic components (e.g., headboard, footboard, side rail accents) with a soft, damp кездеме.
- Mattress and Table Cleaning: Specific cleaning instructions for the mattress and overbed table are not provided. It is recommended to clean them following general guidelines for similar items, typically using a damp cloth with mild disinfectant or soap, and allowing them to air dry completely.
- Майлоо: Periodically check the manual crank mechanisms and wheel axles for smooth operation. Apply a small amount of silicone-based lubricant if any stiffness is observed.
- Аппараттык камсыздоону текшерүү: Regularly inspect all bolts, nuts, and fasteners to ensure they are tight. Re-tighten if necessary.
- Дөңгөлөктү текшерүү: Check wheels for any debris or damage that might impede movement or braking. Clean as needed.
Проблемаларды чечүү
This section addresses common issues you might encounter with your manual hospital bed.
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Crank mechanism is stiff or hard to turn. | Lack of lubrication; minor obstruction; bent component. | Apply silicone-based lubricant to the crank mechanism. Check for and remove any obstructions. If bent, contact customer support. |
| Wheels do not roll smoothly or are difficult to move. | Brakes engaged; debris in wheels; damaged wheel. | Ensure all wheel brakes are disengaged. Remove any hair or debris from the wheel axles. If damaged, contact customer support for replacement. |
| Side rails do not lock securely. | Locking mechanism obstructed or damaged; rail not fully raised. | Ensure the rail is fully raised until it clicks. Check the locking mechanism for any obstructions. If damaged, do not use and contact customer support. |
| Төшөк туруксуз же солкулдаган сезилет. | Loose assembly hardware; uneven floor; damaged frame component. | Check and tighten all assembly bolts and nuts. Ensure the bed is on a level surface. If a frame component is damaged, discontinue use and contact customer support. |
Техникалык шарттар
| Өзгөчөлүк | Деталь |
|---|---|
| Модель номери | CCH-001 |
| Бренд | EDGE |
| Өлчөмдөрү (L x W x Y) | 200 cm x 95 cm x 18 cm (Note: These dimensions may refer to packaged size. Actual assembled dimensions are standard for hospital beds.) |
| Салмагы | 55 кг (121 фунт) |
| Максималдуу жүктөө жөндөмдүүлүгү | 200 кг (440 фунт) |
| Материал | Iron, ABS Plastic |
| Түзөтүүлөр | Manual Backrest (up to 85 degrees), Manual Leg Rest (up to 45 degrees) |
| Мобилдүүлүк | 4 Silent Wheels with Individual Brakes |
| Камтылган аксессуарлар | Mattress, Overbed Table, IV Pole |
| Ассамблея талап кылынат | Ооба |
Кепилдик жана колдоо
For information regarding warranty coverage, technical support, or replacement parts, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.
Manufacturer: Easy Shop Internacional