1. Киришүү
This manual provides comprehensive instructions for the safe and effective use of the AOPUTTRIVER AP-535G Portable Ammonia Gas Detector. This device is designed to accurately measure ammonia (NH3) gas concentrations, ambient temperature, and relative humidity in various environments. Please read this manual thoroughly before operating the device to ensure proper function and safety.

Сүрөт 1.1: Бүттүview of the AOPUTTRIVER AP-535G Ammonia Gas Detector highlighting its core functions: Ammonia Gas Monitor, Humidity, Temperature, Audible Alarm, C/F Selection.
2. Коопсуздук маалыматы
Observe the following safety precautions to prevent injury and avoid damage to the device:
- Do not attempt to open or modify the device. Internal components are not user-serviceable.
- Электр тогуна урунуп же бузулуп калбашы үчүн, түзмөктү суудан жана башка суюктуктардан алыс кармаңыз.
- Аппаратты белгиленген температура жана нымдуулук диапазондорунда иштетиңиз.
- Ensure the device is charged using the provided USB cable and a compatible power adapter.
- This device is for monitoring purposes only and should not be used as a substitute for professional safety equipment or procedures.
- Avoid exposing the sensor to extreme concentrations of gas, which may cause damage or inaccurate readings.
3. Продукт бүтүп калдыview
3.1 Пакеттин мазмуну
- AOPUTTRIVER AP-535G Ammonia Gas Detector
- USB Type-C кубаттоочу кабель
- User Manual
3.2 Негизги өзгөчөлүктөрү
- Sensitive & High-Precision: Equipped with a professional electrochemical sensor for 0-100 ppm NH3 detection with +/-5% accuracy and 0.1ppm resolution. Response time is less than 120 seconds.
- Adjustable Alarm Settings: Features sound and light dual alarms with customizable alarm thresholds.
- Жарыктандырылган LCD дисплейи: A 4.3-inch backlit LCD provides clear readings in various lighting conditions.
- Humidity & Thermometer: Measures indoor temperature (-10-50°C, +/-2°C accuracy) and relative humidity (0-95%). Temperature units are switchable between Celsius and Fahrenheit.
- Ар тараптуу жайгаштыруу: Includes a hanging hole and a 180° bracket for desktop or wall mounting.
3.3 Device Layout and Display
Familiarize yourself with the device's display and button functions:

Сүрөт 3.1: Детальдуу view of the AP-535G's display and control buttons, with numbered labels indicating specific functions.
| Жок. | Description |
|---|---|
| 1 | Ammonia chemical formula (NH3) |
| 2 | Ammonia concentration display area |
| 3 | Ammonia gas unit (PPM) |
| 4 | Level 1 alarm indication (AL1) |
| 5 | Level 2 alarm indication (AL2) |
| 6 | Backlight display indicator |
| 7 | Батарея кубаттуулугунун көрсөткүчү |
| 8 | Температура бирдиги (°C/°F) |
| 9 | Температуранын маанисин көрсөтүү аймагы |
| 10 | Humidity unit (%RH) |
| 11 | Humidity value display area |
| 12 | Кубат баскычы |
| 13 | Alarm and backlight button |
| 14 | Mode and up button |
| 15 | °C/°F conversion and down button |
4. Орнотуу
4.1 Аппаратты заряддоо
The AP-535G is equipped with a rechargeable battery. Before first use, or when the battery indicator shows low power, charge the device:
- Connect the provided USB Type-C cable to the charging port on the side of the device.
- USB кабелинин экинчи учун стандарттуу USB кубат адаптерине (кошулмада жок) же компьютердин USB портуна туташтырыңыз.
- Дисплейдеги батареянын индикатору кубаттоо абалын көрсөтөт. Толук кубаттоо, адатта, бир нече саатка созулат.
- Толук заряддалгандан кийин, заряддоо кабелин ажыратыңыз.

Image 4.1: The AP-535G device highlighting its USB Type-C charging port and overall dimensions.
4.2 Баштапкы күйгүзүү
Аппаратты күйгүзүү үчүн:
- Press and hold the Power button (12) located at the bottom left of the device.
- The LCD display will illuminate and begin a self-calibration process.
- Allow the device to stabilize for approximately 120 seconds for accurate readings.
5. Операция
5.1 Күйгүзүү/өчүрүү
- Күйгүзүү: Press and hold the Power button (12) until the display turns on.
- Өчүрүү: Press and hold the Power button (12) until the display turns off.
5.2 Өлчөөлөрдү окуу
Once powered on and stabilized, the device will continuously display:
- Ammonia concentration in PPM (2).
- Relative humidity in %RH (11).
- Temperature in °C or °F (9).
5.3 Adjusting Alarm Settings
The device features two alarm levels (AL1 and AL2) that can be set to alert you when ammonia concentration exceeds a specified threshold. When an alarm is triggered, the device will emit a beep and flash its LED light.

Image 5.1: The AP-535G illustrating its sound and light dual alarm system, which activates when preset ammonia levels are exceeded.
- Press the Mode button (14) to cycle through display modes until 'AL1' or 'AL2' appears.
- While 'AL1' or 'AL2' is displayed, press the Alarm button (13) to enter setting mode. The current alarm value will flash.
- Use the Mode button (14) to increase the value and the °C/°F button (15) to decrease the value.
- Press the Alarm button (13) again to confirm the setting and exit.
5.4 Switching Temperature Units (°F/°C)
Цельсий жана Фаренгейт температура бирдиктерин алмаштыруу үчүн:
- Briefly press the °C/°F button (15). The temperature unit on the display will change accordingly.
5.5 Жарыкты башкаруу
The device features a backlight for improved visibility in low-light conditions.
- Briefly press the Alarm button (13) to toggle the backlight on or off.

Image 5.2: The AP-535G's 4.3-inch LCD display, demonstrating its backlight function for clear visibility in various lighting conditions.
6. Техникалык тейлөө
6.1 Тазалоо
Түзмөктүн иштешин жана көрүнүшүн сактоо үчүн:
- Түзмөктүн сыртын жумшак, кургак чүпүрөк менен сүртүңүз.
- Do not use abrasive cleaners, solvents, or corrosive chemicals.
- Ensure no liquids enter the sensor openings or charging port.
6.2 Батареяга кам көрүү
- Батареянын иштөө мөөнөтүн узартуу үчүн түзмөктү үзгүлтүксүз кубаттап туруңуз.
- Батареяны бат-баттан толук түгөтүп коюудан алыс болуңуз.
- If storing the device for an extended period, charge it to approximately 50% and recharge every few months.
7. Кыйынчылыктарды
If you encounter issues with your AP-535G, refer to the following common problems and solutions:
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Түзмөк күйбөйт | Батареянын аздыгы; аппараттын бузулушу | Аппаратты толук заряддаңыз. Эгер көйгөй чечилбесе, колдоо бөлүмүнө кайрылыңыз. |
| Так эмес окуулар | Sensor not stabilized; sensor obstruction; extreme environmental conditions | Allow 120 seconds for stabilization after power-on. Ensure sensor is clear. Operate within specified temperature/humidity. |
| Сигнал чыкпай жатат | Alarm levels set too high; sound disabled | Check and adjust alarm thresholds (AL1, AL2). Ensure sound is enabled (if applicable). |
| Дисплей күңүрт же бош | Backlight off; low battery | Press the Alarm button (13) to toggle backlight. Charge the device. |
8. Техникалык шарттар

Image 8.1: Technical parameters of the AP-535G Ammonia Gas Detector, including gas detection type, measuring range, resolution, and response time.
| Параметр | Нарк |
|---|---|
| Модель номери | AP-535G-US |
| Газды аныктоо | Аммиак (NH3) |
| Өлчөө диапазону | 0-100 промилле |
| Резолюция | 0.1 промилле |
| Тактык | +/-5% |
| Жооп убактысы | 120 секунддан аз |
| Температура диапазону | -10-50 ° C (14-122 ° F) |
| Температуранын тактыгы | +/- 2 ° C |
| нымдуулук колому | 0-95% RH |
| Дисплей | 4.3 дюймдук арткы жарыктандырылган LCD дисплей |
| Power Source | Заряддалуучу Батарея (USB Type-C) |
| Элемент Салмагы | 0.8 фунт (болжол менен 363 г) |
| Пакеттин өлчөмдөрү | 7.28 x 5.98 x 2.32 дюйм |
| Өндүрүүчү | AOPUTTRIVER |
9. Кепилдик жана колдоо
AOPUTTRIVER products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official AOPUTTRIVER webсайт. Сатып алуу квитанциясын кепилдик дооматтары үчүн сатып алуунун далили катары сактаңыз.