1. Киришүү
The Vertiv Liebert IntelliSlot RDU120 Network Card is an advanced remote monitoring adapter designed to enhance the management capabilities of Vertiv products. This card facilitates secure and flexible communication, enabling real-time data access and system status monitoring for critical infrastructure.
1.1 Продукт бүттүview
The RDU120 provides web access and data transmission via industry-standard protocols such as SNMP, Modbus, and BACNet. It supports environmental monitoring through compatible Geist Sensors for parameters like temperature, humidity, leak detection, and contact closures. Its UL2900-1 cybersecurity certification ensures secure online communication and data integrity.
1.2 Негизги өзгөчөлүктөрү
- UL2900-1 Cybersecurity Certified: Ensures secure online communication.
- Secure Boot with Hardware Trust Anchor: Prevents unauthorized software tampring.
- Ийкемдүү байланыш: Supports SNMP, Modbus, and BACnet protocols.
- Standard RESTful API Support: Facilitates easy configuration and updates.
- 1 Gb Ethernet: Compatible with modern network environments and web браузерлер.
- Экологиялык мониторинг: Supports Geist Sensors for various environmental parameters.
2. Коопсуздук маалыматы
Please read and understand all safety instructions before installing or operating the Vertiv Liebert IntelliSlot RDU120 Network Card. Failure to follow these instructions may result in injury, damage to the product, or voiding of the warranty.
- Ensure the host device is powered off and disconnected from the power source before installation.
- Handle the network card by its edges to avoid touching electronic components.
- Use appropriate electrostatic discharge (ESD) precautions when handling the card.
- Do not expose the card to moisture or extreme temperatures.
- Only use accessories and cables approved by Vertiv.
3. Пакеттин мазмуну
Пакетти ачканда бардык буюмдар бар экенин жана бузулбаганын текшериңиз:
- Vertiv Liebert IntelliSlot RDU120 Network Card
- Ыкчам баштоо колдонмосу (эгер бар болсо)
- Монтаждоо бурамалар (эгер бар болсо)
Эгерде кандайдыр бир буюмдар жок болсо же бузулуп калса, дароо жеткирүүчүңүзгө кайрылыңыз.
4. Продукт бүтүп калдыview
Familiarize yourself with the physical components and ports of the RDU120 Network Card.

4.1-сүрөт: Жалпысынан view of the RDU120 Network Card, displaying the circuit board and connectors.

4.2-сүрөт: Бурчтуу view of the RDU120, showing the front panel and card profile.

4.3-сүрөт: Детальдуу view of the RDU120 front panel, indicating port labels.

4.4-сүрөт: Каптал view of the RDU120, showing its form factor and mounting bracket.
4.1 Front Panel Ports and Indicators
- Ethernet порту (RJ45): For 1 Gb network connectivity.
- USB порт: For local configuration or firmware updates.
- RS-485/232 Ports: For serial communication with compatible devices.
- Activity/Link LEDs: Indicate network activity and connection status.
5. Орнотуу
5.1 Орнотуу кадамдары
- Power Down Host Device: Ensure the Vertiv equipment where the RDU120 will be installed is completely powered off and unplugged.
- Locate IntelliSlot Bay: Identify the dedicated IntelliSlot bay on your Vertiv device.
- Insert RDU120 Card: Carefully slide the RDU120 Network Card into the IntelliSlot bay until it is fully seated. Ensure the front panel aligns with the device's chassis.
- Коопсуз карта: Use any provided screws or retention clips to secure the card in place.
- Тармак кабелин туташтыруу: Connect a standard Ethernet cable from your network switch or router to the Ethernet port on the RDU120 front panel.
- Power On Host Device: Reconnect power to the Vertiv equipment and power it on. The RDU120 will initialize with the host device.
5.2 Баштапкы конфигурация
Upon initial power-up, the RDU120 will typically obtain an IP address via DHCP. If DHCP is not available or a static IP is required, refer to the detailed configuration guide available on the Vertiv support webсайт.
- кирүү Web Интерфейс: ачуу а web browser and enter the IP address of the RDU120. If DHCP is used, you may need to use a network scanner or the host device's interface to find the assigned IP.
- Демейки эсептик дайындар: Use the default username and password provided in the product documentation for initial login. Change these immediately for security.
- Тармак орнотуулары: Configure static IP address, subnet mask, gateway, and DNS servers as per your network requirements.
6. Иштөө
6.1 Web Интерфейс навигациясы
The RDU120's web interface provides comprehensive control and monitoring capabilities. Navigate through the menus to access various settings and data points.
- Куралдар тактасы: Ашыкча камсыз кылатview of system status, alarms, and key parameters.
- Мониторинг: View real-time data, historical trends, and sensor readings.
- Конфигурация: Adjust network settings, user accounts, and communication protocols.
- Alarms & Notifications: Set up alarm thresholds and configure email/text message alerts.
6.2 Monitoring Data
The RDU120 supports various protocols for data integration with Building Management Systems (BMS) and network monitoring tools.
- SNMP (Жөнөкөй тармак башкаруу протоколу): Use SNMP v1/v2c/v3 for polling data and receiving traps. Refer to the MIB file for OID definitions.
- Modbus: Access data via Modbus TCP/IP. Consult the Modbus register map for details.
- BACnet: Integrate with BACnet/IP systems for building automation.
6.3 Alarm and Notification Management
Configure the RDU120 to send alerts for critical events:
- Define alarm thresholds for monitored parameters (e.g., temperature, voltagжана).
- Configure email recipients and SMTP server settings for email notifications.
- Set up SMS gateway for text message alerts (if supported by your service provider).
6.4 Айлана-чөйрөнү көзөмөлдөө
When connected to compatible Geist Sensors, the RDU120 can monitor environmental conditions:
- Температура жана нымдуулук: Monitor ambient conditions in server racks or rooms.
- Агышты аныктоо: Detect water leaks to prevent equipment damage.
- Door Closures: Monitor access to cabinets or rooms.
7. Техникалык тейлөө
7.1 Микропрограмма жаңыртуулары
Regularly check the Vertiv support webакыркы микропрограмма жаңыртуулары үчүн сайт. Микропрограмма жаңыртуулары жаңы функцияларды, иштин натыйжалуулугун жакшыртууларды жана коопсуздукту жакшыртууларды камсыз кыла алат.
- Тиешелүү микропрограмманы жүктөп алыңыз file from the Vertiv webсайт.
- Access the firmware update section in the RDU120 web интерфейс.
- Follow the on-screen instructions to upload and install the firmware. Do not power off the device during the update process.
7.2 Системанын камдык көчүрмөсүн сактоо жана калыбына келтирүү
It is recommended to back up the RDU120's configuration settings periodically, especially before major changes or firmware updates.
- Export configuration settings from the web интерфейс.
- Store the backup file коопсуз жерде.
- Use the restore function to revert to a previous configuration if needed.
8. Кыйынчылыктарды
This section provides solutions to common issues you might encounter with the RDU120 Network Card.
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Кирүү мүмкүн эмес web интерфейс. | туура эмес IP дареги; Тармакка туташуу маселеси; Брандмауэр кирүүгө бөгөт коюуда. | Verify IP address; Check network cable and switch; Disable temporary firewall for testing; Ensure RDU120 is powered on. |
| No data via SNMP/Modbus/BACnet. | Protocol not enabled; Incorrect configuration; Network routing issue. | Ensure protocol is enabled in RDU120 settings; Verify IP addresses and port numbers; Check network routes and firewalls. |
| Alarms not being sent. | Incorrect notification settings; SMTP server issues; Email address errors. | Verify alarm thresholds and notification recipients; Test SMTP server connectivity; Check spam folders. |
| Card not detected by host device. | Card not fully seated; Incompatible host device; Card malfunction. | Reseat the card firmly; Consult host device compatibility list; Contact Vertiv support if issue persists. |
For more complex issues, refer to the comprehensive troubleshooting guide on the Vertiv support website or contact Vertiv technical support.
9. Техникалык шарттар
Technical specifications for the Vertiv Liebert IntelliSlot RDU120 Network Card:
| Атрибут | Нарк |
|---|---|
| Продукциянын өлчөмдөрү | 5.2 x 2.97 x 1.45 дюйм |
| Элемент Салмагы | 5.9 унция |
| ASIN | B0F2MN6WTB |
| Элемент моделинин номери | RDU120 |
| Дата биринчи жеткиликтүү | 27-март, 2025-жыл |
| Өндүрүүчү | Vertiv |
| Бренд | Vertiv |
| UPC | 767041039627 |
10. Кепилдик жана колдоо
10.1 Кепилдик маалыматы
Vertiv products are backed by a standard limited warranty. For specific warranty terms and conditions applicable to your RDU120 Network Card, please refer to the warranty documentation included with your purchase or visit the official Vertiv webсайт.
10.2 Техникалык колдоо
For technical assistance, product inquiries, or troubleshooting beyond the scope of this manual, please contact Vertiv Technical Support. Support contact information can be found on the official Vertiv webсайт:
Vertiv расмий Webсайт: www.vertiv.com
Please have your product model number (RDU120) and serial number ready when contacting support.





