Ваттс LF25AUB-Z3

Watts LF25AUB-Z3 Water Pressure Reducing Valve Instruction Manual

Model: LF25AUB-Z3 | Brand: Watts

1. Продукт бүтүп калдыview

The Watts LF25AUB-Z3 Series 1" Lead-Free Water Pressure Reducing Valve is engineered to safeguard plumbing systems and optimize water consumption in various settings, including commercial, industrial, and residential applications. This standard model effectively reduces incoming water pressure to a manageable, preset level. Its design incorporates a replaceable seat module, NPT threaded female union inlet by NPT female outlet connections, and a bypass feature to manage thermal expansion pressure. The valve is constructed from lead-free cast copper silicon alloy, ensuring compliance with safety standards.

2. Негизги өзгөчөлүктөрү

3. Техникалык шарттар

АтрибутНарк
Модель номериLF25AUB-Z3
Өлчөмү1 дюйм
МатериалLead-Free Cast Copper Silicon Alloy (Brass)
Inlet Connection түрүЯдролук куралдарды таратпоо келишиминин аялдар биримдиги
Розетка туташуу түрүNPT Аял
Жөнгө салынуучу басым диапазону25 – 75 psi (172 – 517 кПа)
Стандарттык жөндөө50 psi (345 кПа)
Максималдуу иштөө басымы300 psi (20.7 бар)
Температура диапазону33°F (0.5°C) менен 180°F (82°C)
Өлчөмдөрү (L x W x Y)3.9 x 7.4 x 8.5 дюйм
Элемент Салмагы5.05 фунт

4. Орнотуу жана орнотуу

Proper installation of the Watts LF25AUB-Z3 valve is crucial for optimal performance and longevity. It is recommended that installation be performed by a qualified plumber or technician.

4.1 Алдын ала орнотуу текшерүү тизмеси

4.2 Орнотуу кадамдары

  1. Түтүктү даярдоо: Cut a section of the main water line where the valve is to be installed. Ensure the cut ends are clean and free of burrs.
  2. Клапанды багыттоо: The valve has an arrow indicating the direction of water flow. Ensure the arrow points in the direction of water flow from the main supply into your home. The NPT female union inlet connects to the incoming water supply, and the NPT female outlet connects to the household plumbing.
  3. Жип герметикти колдонуу: Apply an appropriate thread sealant (e.g., Teflon tape or pipe dope) to the male threads of the pipes that will connect to the valve's union and outlet.
  4. Клапанды туташтырыңыз: Securely connect the valve to the plumbing lines. Use pipe wrenches to tighten connections, but do not overtighten to avoid damaging the valve or pipes.
  5. Агышууларды текшерүү: Slowly turn on the main water supply and carefully inspect all connections for leaks. Tighten any leaking connections as needed.
  6. Verify Pressure: Use a pressure gauge connected to a nearby hose bib or test port to verify the outlet pressure. The valve comes factory preset to 50 psi.
End Connection Flexibility for Watts Pressure Reducing Valve

Image: End Connection Flexibility. The valve supports various connection types for simplified installation.

5. Иштөө нускамалары

The Watts LF25AUB-Z3 valve is designed to maintain a consistent outlet pressure. The factory setting is typically 50 psi, but it can be adjusted within its specified range.

5.1 Adjusting Outlet Pressure

  1. Жөндөө бурамасын табыңыз: The pressure adjustment screw is located at the top of the valve, typically covered by a cap or a locknut.
  2. Loosen Locknut (if present): If there is a locknut, loosen it before making adjustments.
  3. басымды жөндөө:
    • үчүн көбөйтүү the outlet pressure, turn the adjustment screw clockwise.
    • үчүн азайтуу чыгуучу басымды түшүрүүдө, жөндөө бурамасын саат жебесине каршы буруңуз.
  4. Монитор басымы: Use a reliable pressure gauge connected to a downstream hose bib or test port to accurately monitor the pressure as you adjust.
  5. Tighten Locknut: Once the desired pressure is set (within the 25-75 psi range), tighten the locknut (if present) to secure the setting.

Note: Avoid setting the pressure too high, as excessive pressure can damage household plumbing and appliances. Most residential plumbing is designed for a maximum of 80 psi.

Tool-Free Pressure Adjustments on Watts Pressure Reducing Valve

Image: Tool-Free Pressure Adjustments. The valve allows for easy pressure adjustments from the top.

6. Техникалык тейлөө

Regular maintenance ensures the continued optimal performance and extends the lifespan of your Watts LF25AUB-Z3 valve.

6.1 Күнүмдүк текшерүүлөр

6.2 Тейлөө

The valve is designed for easy in-line serviceability, featuring a replaceable seat module. For internal servicing or replacement of components, it is highly recommended to contact a certified plumbing professional. Attempting repairs without proper knowledge and tools can lead to damage or improper function.

Fast and Easy Maintenance for Watts Pressure Reducing Valve

Image: Fast & Easy Maintenance. The valve is designed for service directly in line from the top.

7. Кыйынчылыктарды

This section provides general guidance for common issues. For complex problems, consult a qualified plumber.

КөйгөйМүмкүн себепЧечим
High Water Pressure DownstreamValve setting too high; debris in valve; worn diaphragm/seat.Adjust pressure setting (Section 5.1); clean strainer; consult professional for internal inspection/repair.
Low Water Pressure DownstreamValve setting too low; clogged strainer; insufficient incoming pressure.Adjust pressure setting (Section 5.1); clean strainer; check main supply pressure.
Water HammeringPressure fluctuations; air in pipes; valve malfunction.Ensure stable pressure setting; bleed air from system; if persistent, consult professional.
Valve LeakingLoose connections; damaged seals/gaskets; internal component failure.Check and tighten connections; consult professional for seal replacement or internal repair.

8. Продукциянын сүрөттөрү

Watts LF25AUB-Z3 Water Pressure Reducing Valve
Сүрөт 8.1: Алдыңкы view of the Watts LF25AUB-Z3 Water Pressure Reducing Valve.
Кесилген view of Watts LF25AUB-Z3 showing internal components
Figure 8.2: Internal cutaway view illustrating the valve's components, including the spring and diaphragm.
Side view of Watts LF25AUB-Z3 Water Pressure Reducing Valve
8.3-сүрөт: Каптал view of the valve, highlighting the NPT female union inlet.
Watts Pressure Reducing Valve Certified to Perform
Figure 8.4: Certification details for the Watts Pressure Reducing Valve, indicating compliance with industry standards.
Available Sizes for Watts Pressure Reducing Valve
Figure 8.5: Illustration showing the range of available sizes for Watts pressure reducing valves, from 1/2" to 2".
Powerful Pressure Control with Watts Valve
Figure 8.6: Diagram illustrating the powerful pressure control capabilities, managing inlet pressures up to 300 psi and ensuring steady outlet pressure.

9. Кепилдик жана колдоо

For specific warranty information and technical support regarding your Watts LF25AUB-Z3 Water Pressure Reducing Valve, please refer to the official Watts website or contact Watts customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

Watts Customer Service: Сураныч, келиңиз www.watts.com байланыш маалыматы жана колдоо булактары үчүн.

Тектеш документтер - LF25AUB-Z3

Preview Watts LF25AUB-Z3 сериясындагы суу басымын төмөндөтүүчү клапанды орнотуу боюнча нускамалар
Watts LF25AUB-Z3 сериясындагы суу басымын төмөндөтүүчү клапанды орнотуу боюнча кеңири колдонмодо коопсуздук чаралары, орнотуу ыкмалары (типтүү, удаалаш, параллелдүү), жөндөө жол-жоболору, оңдоо комплекттери жана мүчүлүштүктөрдү чечүү боюнча кеңештер кеңири баяндалган. Диаграммалардын жана тетиктердин тексттик сүрөттөмөлөрү камтылган.
Preview Watts LFN45B сериясындагы суу басымын төмөндөтүүчү клапанды орнотуу жана техникалык тейлөө боюнча колдонмо
Watts LFN45B сериясындагы суу басымын төмөндөтүүчү клапанды орнотуу, техникалык тейлөө жана бузулууларды оңдоо боюнча кеңири колдонмо. Коопсуздук эскертүүлөрүн, жөндөө жол-жоболорун жана кепилдик жөнүндө маалыматты камтыйт.
Preview WATTS LFN45B Суу басымын төмөндөтүүчү клапан - Орнотуу жана техникалык тейлөө боюнча колдонмо
WATTS LFN45B суу басымын төмөндөтүүчү клапанды орнотуу, иштетүү жана бузулууларды оңдоо боюнча кеңири колдонмо. Сантехникалык системалар үчүн коопсуздук эскертүүлөрүн, орнотуу көрсөтмөлөрүн, жөндөө жол-жоболорун жана көйгөйлөрдү чечүү боюнча кеңештерди камтыйт.
Preview Watts N55B-M1 жана LFN55B-M1 суу басымын төмөндөтүүчү клапанды орнотуу жана техникалык тейлөө
Watts N55B-M1 жана LFN55B-M1 суу басымын төмөндөтүүчү клапандарды орнотуу, техникалык тейлөө жана мүчүлүштүктөрдү оңдоо боюнча кеңири колдонмо, анын ичинде диаграммалар жана кепилдик маалыматы.
Preview Гидравликалык текшерүү функциясы бар Ваттс басымды төмөндөтүүчү клапан - Дат баспас болоттон жасалган сериялар
Техника бүттүview Watts ACV айкалышкан басымды төмөндөтүүчү жана текшерүүчү клапаны, анын иштешинин чоо-жайы, орнотуу көрсөтмөлөрү жана тиешелүү башкаруу клапандарынын моделдеринин тизмеси.
Preview Watts W-M115 ACV Pressure Reducing Valve: Specification & Installation Guide
Comprehensive guide detailing the specifications, dimensions, flow rates, operating principles, installation, and start-up procedures for the Watts W-M115 ACV Pressure Reducing Valve. Essential information for industrial and commercial applications.