1. Продукт бүтүп калдыview

The Huanyang GT Series Vector Control Variable Frequency Drive (VFD) Inverter is designed for precise motor control in various industrial and machinery applications. This manual provides essential information for safe and efficient operation.

Фронт view of the Huanyang GT Series VFD Inverter

Сүрөт 1: Алдыңкы view of the GT Series VFD Inverter

Техникалык өзгөчөлүктөрү:

  • PID башкаруу: Advanced calculous PID closed-loop arithmetic for quick response and high suitability.
  • Easy PLC Function: Realizes 16 legs of speed and inverter control.
  • RS485 байланыш: Adopts standard international MODBUS main circuit control.
  • Anti-jamming Capability: Extremely strong anti-jamming performance.
  • Low Output Torque: 0.5Hz-150% rating, with good low-speed running ability.
  • Adjustable Carrier: Up to 16KHz for a soundless working environment.
  • Broad Voltage диапазону: Normal operation within 304V-456V.
  • Auto Voltage Регламент (AVR): Ensures inverter load capability.
  • Dead-time Compensation: Auto torque slip compensation function for 180% high torque output at low frequency (0.25Hz).

2. Техникалык шарттар

СпецификацияНарк
Модель номериGT-011G-2
TypeDC/AC инверторлору
Output TypeҮчтүк
Output Current220V / 380V
Чыгуу жыштыгы47-63 Гц
Чыгуу күчү0-400Hz, 0-50Hz/60Hz According to motor setup
Өлчөмү27.5*20.5*23см
СертификацияCE
Applicable Motor Power≤7.5KW (10hp)
Applicable Motor Rated Current<50 amps
Киргизүү көлөмүtage Support (220V Version)220VAC (+/-5%) 1 or 3 phase
Киргизүү көлөмүtage Support (380V Version)380V (+/-5%)
Output Voltage (220V Version)3 phase 220V
Output Voltage (380V Version)3 phase 380V
Circuit Breaker Suggestion80A
Wire Specification Suggestion9 AWG
Dimensions diagram of the VFD inverter

Figure 2: VFD Inverter Dimensions

3. Орнотуу жана зымдар

3.1 Алгачкы текшерүү

Before installation, inspect the VFD for any physical damage. Ensure all components are present as listed in the package contents.

3.2 Motor Voltage Орнотуу

Ensure your motor's voltage is correctly configured. For motors that support both 220V and 440V, set it to the low voltage (220V) configuration. This typically involves connecting the X-Y-Z terminals together and the U-V-W terminals together, as indicated on your motor's nameplate.

3.3 Power and Motor Connections

Refer to the wiring diagrams below for proper connection. Always ensure power is disconnected before making any wiring changes.

Wiring diagram for 220VAC input to a three-phase asynchronous motor

Figure 3: Basic Wiring for 220VAC Input to a Three-Phase Motor

  • Input Power (220V Single Phase): Connect the two live wires of your 220V AC power supply to the 'R' and 'S' terminals on the VFD.
  • Жерге туташуу: Connect the ground wire to the 'E' terminal (green wire in diagrams).
  • Мотор чыгаруу: Connect the three-phase motor wires to the 'U', 'V', and 'W' terminals. The order of these connections determines the motor's rotation direction. If the motor rotates in the wrong direction, you can swap any two of these three wires to reverse the rotation.
Wiring diagram for single-phase 220V input to VFD

Figure 4: Single-Phase 220V Input Wiring

Typical wiring diagram for the VFD, showing control circuit terminals

Figure 5: Typical Wiring Diagram with Control Circuit Terminals

3.4 Башкаруу схемасынын терминалдары

The VFD features control circuit terminals for external control. These include connections for 485+, 485-, +10V, GND, S1-S7, AO1, AO2, COM, PW, +24V, HDI, HDO, RO1A, RO1B, RO1C.

Деталдаштырылган view of VFD control circuit terminals

Figure 6: Control Circuit Terminals

3.5 Programming Parameters (Example for 220V, 8.5A, 1720 RPM Motor)

The following parameters are crucial for initial setup. Consult the full manual for detailed parameter descriptions.

ПараметрНаркDescription
PD0131Restores factory defaults. Recommended to start with this.
PD00560Maximum operating frequency (Hz).
PD00460Base frequency (Hz).
PD00360Reference frequency (Hz).
PD008220Максималдуу чыгаруу көлөмүtage (V).
PD1428.5Motor rated current (Ampс).
PD141220Мотор номиналдык томtage (Volts).
PD1441720Motor rated RPM.
PD1434Number of motor poles (calculated as 7200 / RPM).
PD0143Acceleration time (seconds).
PD0153Deceleration time (seconds).
PD0011Enables external switch control for RUN/STOP.
PD04402Terminal for Forward control (connect to DCM).
PD04503Terminal for Reverse control (connect to DCM).

3.6 External Control (Forward/Reverse Switch)

If PD001 is set to 1, the VFD will respond to external switch inputs for motor control. A simple rotary switch or toggle switch can be used to connect the DCM terminal to the designated forward (PD044) or reverse (PD045) control terminals.

Video 1: VFD Setup and Operation Demonstration. This video demonstrates the wiring and programming parameters for a Huanyang VFD, including motor voltage setup, input/output connections, and setting parameters for frequency, ampэраж, тtage, RPM, acceleration/deceleration, and external switch control for forward/reverse.

4. Операция

4.1 Башкаруу панели

The VFD features a digital display and a keypad for direct control and parameter adjustment.

Control panel layout with button labels

Figure 7: VFD Control Panel

  • Санариптик дисплей: Shows current frequency, parameters, and error codes.
  • PROG/ESC Key: Enters/exits programming mode, escapes current menu.
  • SHIFT баскычы: Shifts cursor during parameter editing.
  • RUN баскычы: Starts motor operation.
  • DATA SET Key: Параметрлердин өзгөрүшүн ырастайт.
  • QUICK/JOG Key: Shortcut key, often used for jogging the motor.
  • STOP/RST Key: Stops motor operation, resets faults.
  • Өйдө/төмөн жебелер: Navigate menus, adjust parameter values.

4.2 Негизги операция

  1. Күйгүзүү: Ensure all wiring is correct and secure before applying power.
  2. Моторду ишке киргизүү: Press the 'RUN' button on the control panel, or activate the external switch if configured (PD001=1).
  3. Ылдамдыкты жөндөө: Use the Up/Down arrow keys to adjust the output frequency, thereby changing the motor speed.
  4. Моторду токтотуу: Press the 'STOP/RST' button, or deactivate the external switch.

5. Техникалык тейлөө

5.1 Муздатуу системасы

The VFD is equipped with a DC cooling fan and an aluminum base for efficient heat dissipation. Ensure the fan vents are clear of obstructions to maintain proper airflow and prevent overheating.

VFD with DC cooling fan and aluminum base

Figure 8: DC Cooling Fan and Aluminum Base

  • Regularly clean dust and debris from the fan and heat sink fins.
  • Ensure the VFD is installed in an environment with adequate ventilation.

5.2 Жалпы кам көрүү

  • Keep the VFD clean and dry. Avoid exposure to moisture, corrosive gases, or excessive dust.
  • Бардык зымдардын туташууларынын бекемдигин жана эскирүү же бузулуу белгилерин мезгил-мезгили менен текшерип туруңуз.
  • The control board is removable for maintenance or replacement.
VFD with removable control board

Figure 9: Removable Control Board

6. Кыйынчылыктарды

6.1 Жалпы маселелер

  • VFD Trips Out During Deceleration: If the VFD trips during rapid deceleration, the deceleration time (PD015) may be too short for the motor's inertia. Increase the value of PD015. For very fast deceleration requirements, an external braking resistor may be necessary. Refer to the VFD's comprehensive manual for resistor sizing and connection instructions.
  • Incorrect Motor Rotation: If the motor spins in the wrong direction after initial setup, swap any two of the three output wires (U, V, W) connected to the motor.
  • VFD Not Responding to RUN Button: If you have configured external control (PD001=1), the 'RUN' button on the VFD's panel will be disabled. Ensure your external switch is correctly wired and activated.

7. Кепилдик жана колдоо

The Huanyang GT Series VFD Inverter comes with a 3-year limited warranty. For technical support or warranty claims, please contact your seller or the manufacturer directly.

8. Колдонуучунун кеңештери

  • Motor Nameplate Data: Always refer to your motor's nameplate for accurate voltage, amperage, and RPM values when programming the VFD.
  • Тышкы көзөмөл: Utilizing an external rotary or toggle switch for forward/reverse control can enhance safety and convenience, especially in workshop environments.
  • Ылдамдануу/Байлоо: Adjusting the acceleration (PD014) and deceleration (PD015) times is crucial for smooth motor operation and to prevent VFD trips. Start with longer times and gradually decrease them if faster response is needed.
  • Муздатуу: Ensure adequate ventilation around the VFD to prevent overheating, which can prolong the life of the unit.

Тектеш документтер - GT-011G-2

Preview Huanyang GT Series Inverter Manual - Орнотуу, иштетүү жана тейлөө боюнча колдонмо
Huanyang GT Series Inverter үчүн комплекстүү окуу куралы, техникалык өзгөчөлүктөрүн, орнотууну, зымдарды, эксплуатациялоону, көйгөйлөрдү чечүү жана тейлөөнү камтыйт. Huanyang VFD колдонуучулары үчүн негизги колдонмо.
Preview Huanyang GT Series Variable Frequency Drive (VFD) 0.75kW-2.2kW Техникалык мүнөздөмөлөрү
GT-1R5G-2, GT-2R2G-2, GT-0R7G-4, GT-1R5G-4 жана GT-2R2G-4 сыяктуу Huanyang GT Series Variable Frequency Drive (VFD) моделдери үчүн деталдуу техникалык мүнөздөмөлөр, өзгөчөлүктөр, тиркемелер жана зымдар диаграммалары. Терминалдык сүрөттөмөлөрдү, башкаруу функцияларын жана физикалык мүнөздөмөлөрдү камтыйт.
Preview Huanyang SL-Vector сериясындагы инвертордун колдонуучу колдонмосу
Huanyang SL-Vector сериясындагы инверторлор үчүн кеңири колдонуучу колдонмосу, анда өзгөрүлмө жыштыктагы жетектөөчү колдонмолор үчүн функциялар, мүнөздөмөлөр, орнотуу, иштетүү жана көйгөйлөрдү чечүү боюнча кеңири маалымат берилген.
Preview Хуаньян инверторунун иштөө боюнча колдонмосу: коопсуздук, орнотуу жана мүнөздөмөлөрү
Хуаньян жалпы максаттагы инверторлору үчүн коопсуздук, орнотуу, зымдар, мүнөздөмөлөр жана оптималдуу иштөө үчүн мүчүлүштүктөрдү оңдоо боюнча кеңири колдонмо.
Preview Хуаньян инверторун орнотуу боюнча колдонмо: Шпиндл жана асинхрондуу мотор туташуулары
This guide details the connection procedures for Huanyang HY Series Variable Frequency Drives (VFDs) with water-cooled spindle motors and three-phase asynchronous motors. It covers wiring, essential parameter settings for 400Hz operation, and technical support contact information.
Preview Huanyang HY Series VFD Simple Manual - Operation and Parameter Guide
A concise guide to the Huanyang HY Series Variable Frequency Drive (VFD), covering terminal configurations, keypad operations, parameter settings, and common operational scenarios for motor speed control.